Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Flow Measurement Multiple Choice Questions
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Flow Measurement Multiple Choice Questions

Flow Measurement Multiple Choice Questions

Last updated: February 2, 2019 11:05 pm
Editorial Staff
Multiple Choice Questions
3 Comments
Share
3 Min Read
SHARE

Flow Measurement Multiple Choice Questions

Question 1

Which of the following flow-measuring elements is inherently linear and requires no signal characterization (e.g. sqaure-root extraction) anywhere in the loop?

(A) Target
(B) Venturi
(C) Orifice plate
(D) Pitot tube
(E) Turbine

Answer : E

Question 2

Bernoulli’s Equation is a mathematical expression of:

(A) The ratio of kinetic to viscous forces in a flow stream
(B) Friction loss as fluid moves through a rough pipe
(C) Potential and kinetic energies in a flow stream
(D) Fluid density and compressibility in a restriction
(E) Vertical height and pressure for a static fluid

Answer : C

Question 3

As an incompressible fluid moves through a restriction,

(A) Velocity decreases and pressure increases
(B) Velocity increases and pressure increases
(C) Velocity increases and pressure remains the same
(D) Velocity increases and pressure decreases
(E) Velocity decreases and pressure remains the same

Answer : D

Question 4

A flag flapping in the breeze illustrates what type of dynamic fluid effect?

(A) Cavitation
(B) Vortex shedding
(C) Transitional flow
(D) Coriolis effect
(E) Laminar flow

Answer : B

Question 5

For accurate operation, orifice plate flowmeters require:

(A) Laminar flow
(B) Fully-developed turbulent flow
(C) Swirls and eddies in the flow stream
(D) Transitional flow
(E) Plug flow

Answer : B

Question 6

A magnetic flowmeter will not properly measure the flow rate of:

(A) Dirty water
(B) Milk
(C) Oil
(D) Caustic
(E) Acid

Answer : C

Question 7

Based on the relative positions of transmitter and orifice plate, this flow-measuring installation is suitable for:

Orifice flow-measuring installation

(A) Slurry flow
(B) Water or oil flow
(C) Gas flow
(D) Steam flow
(E) Laminar flow

Answer : C

Question 8

The purpose for providing ample straight-pipe lengths before and after a flowmeter is to:

(A) Dampen pipe vibrations generated near elbows
(B) Stabilize the flow profile within the flowmeter
(C) Amplify the coriolis effect for better rangeability
(D) Prevent cavitation
(E) Minimize choking under high-flow conditions

Answer : B

Question 9 

A ∆P transmitter calibrated for a range of 0 to 100 ”H2O measures liquid flow through an orifice plate from 0 to 1200 GPH. Calculate the new calibration range for the transmitter if we desire to decrease the flow measurement range to 0 to 700 GPH, using the same orifice plate.

(A) 0 to 34.03” H2O
(B) 0 to 76.38” H2O
(C) 0 to 171.4” H2O
(D) 0 to 293.9” H2O
(E) 0 to 58.33” H2O

Answer : A

Question 10 

Identify which of the following flowmeters inherently measures mass flow rate:

(A) Thermal
(B) Magnetic
(D) Flow nozzle
(D) Vortex
(E) Venturi tube

Answer : A

Credits : by Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Recommended Articles

Fourier Transform NMR Spectroscopy Questions & Answers
Spectrum Analysis of Sampling Process
Nitrogen Oxides Questions & Answers
Nyquist Stability Criterion
Liquid Chromatography Questions & Answers
Electron Probe Microanalyser Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
3 Comments
  • Mohamed Hashem says:
    March 8, 2020 at 8:42 pm

    Very useful questions to concentrate the info explained

    Reply
  • Sou says:
    September 29, 2022 at 12:27 pm

    This is wonderful and I enjoyed studying all these, thank you very much.

    Reply
  • mostafa says:
    July 12, 2023 at 11:18 am

    the question :A ∆P transmitter calibrated for a range of 0 to 100 ”H2O measures liquid flow through an orifice plate from 0 to 1200 GPH. Calculate the new calibration range for the transmitter if we desire to decrease the flow measurement range to 0 to 700 GPH, using the same orifice plate.

    (A) 0 to 34.03” H2O
    (B) 0 to 76.38” H2O
    (C) 0 to 171.4” H2O
    (D) 0 to 293.9” H2O
    (E) 0 to 58.33” H2O
    answer E

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • William Snyder on Top Non-PLC Certification Courses for Automation Professionals
  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Temperature Measurement Multiple Choice Questions

Temperature Measurement Multiple Choice Questions

State Variable Analysis and Design

Solution of State Equations

Pneumatic Systems Objective Questions

Pneumatic Systems Objective Questions

Pneumatic Control Mechanisms Objective Questions

Pneumatic Control Mechanisms Objective Questions

Analyzers Questions and Answers

Dissolved Oxygen Analyzer Questions and Answers

Chromatography Questions & Answers

High Pressure Liquid Chromatography Questions & Answers

Stability in Frequency Domain

Cascade Compensation in Frequency Domain

Analyzers Questions and Answers

Ionization of Gases Questions and Answers

More Articles

Vortex Flow Meter Animation

Basic Working Principle of Vortex Flowmeter

What is Linear Electric Motor

What is Linear Electric Motor?

TP Timer in CodeSys

Timers in Codesys – Timer ON, Timer OFF, Pulse Timer

pH Analyzers Interview Questions Answers

pH Analyzer Interview Questions and Answers

Analog Electronics Objective Questions

Analog Electronics Objective Questions – Set 1

Optical power loss testing

Fiber Optic Cable Testing

Infrared Gas Detectors Principle

Infrared Gas Detectors Working Principle

Process Automation

What is Process Automation? – Simple Automation Example

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?