Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Circuit Breaker Making Capacity
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > Circuit Breaker Making Capacity

Circuit Breaker Making Capacity

Last updated: September 19, 2016 1:55 am
Editorial Staff
Electrical Basics
No Comments
Share
2 Min Read
SHARE

During short circuit, circuit breaker contacts opens and automatically closes after few cycles to determine whether the fault is cleared. 90% of the faults occur in power system are transient in nature and lasts for few cycles and clears on its own eg: touching of transmission lines with each other beacause of wind, touching of tree branches to transmission line momentarily, etc. Such faults clears on its own and after the transient power system restores to normal operation.

Circuit Breaker Making Capacity
Circuit Breaker Making Capacity

It is not advised to open the breaker contacts and isolate the line for such small transients. Therefore auto re-closers are employed which when relay senses the fault trips the circuit breaker contacts. After some time breaker contacts again try to close, if there is no fault in that instant power system restores to normal operation. However if fault further exists circuit breaker contacts open up permanently until it is reset. The cycles of closing and opening is designed  for the circuit breaker depends on the application.

Therefore circuit breaker should close under short circuit condition. The MAKING CAPACITY of the circuit breaker depends on the ability to withstand the effects of electromagnetic forces which which are proportional to the square of the peak value of the making current. Making current of circuit breaker when closed on short circuit is the peak value of maximum current wave (including dc component) in the first cycle of the current after the circuit is closed by the breaker

For determining the making current of the circuit breaker we must multiply symmetrical breaking current by (2)1/2 to convert to peak value from rms value. and then by 1.8 to take into account the doubling effect of maximum asymmetry.

Rated Making Current = 1.8 x (2)1/2 rated short circuit breaking current

                                   = 2.55 x rates short circuit breaking current

                                   = 2.55 x symmetrical breaking capacity

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Variable Frequency Drive (VFD) Working Principle
Partial Discharge in Power Lines and its Detection through Sensors
Lightning Arrester Basics and Terminology
Electrical Energy Management System and SCADA in Power System
Electrical Drawings
VFD Simulator Download – Free Yaskawa V1000 Software
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Why is the Humming Sound Produced in Transformer?
Difference Between RCCB and MCCB
How does an Electric Motor Operate? – AC Motor Fundamentals
Advantages & Disadvantages of Fuse in a Electrical Circuit
What is an Inductor? – Types of Inductors
Difference between UPS and Stabilizer?
Difference Between Permittivity and Permeability
What is a Wave Trap? – Power Line Carrier Communication

Keep Learning

Difference between RCCB and RCBO

Difference between RCCB and RCBO

Dahlander Motor

Dahlander Motors – Principle, Advantages, Disadvantages

What is an Electrical Drive

What is an Electrical Drive? Types, Advantages, Disadvantages

Advantages of Valve Regulated Lead Acid (VRLA) Batteries

Advantages of Valve Regulated Lead Acid (VRLA) Batteries

Automatic Circuit Recloser

What is Automatic Circuit Recloser? Principle and Types

What is a Lightning Arrester? How does it work?

Difference between Power Cables and Signal Cables

Difference between Power Cables and Signal Cables

What is Air Circuit Breaker

What is an Air Circuit Breaker? Working Principle & Applications

Learn More

Capacitive Tank Gauges

Capacitive Tank Gauges

Electrical Machines Questions and Answers

Polyphase Induction Motors Quiz

Alarm Chattering

Categorization of Alarms in a Process Plant

Types of Circuit Breakers

Types of Circuit Breakers, Advantages, Disadvantages

DC Circuit

Main differences between Sinking and Sourcing Circuits

Grounding or Earthing Scheme in DCS or PLC Systems

Grounding or Earthing Scheme in DCS or PLC Systems

Digital Electronics Multiple Choice Questions

Shift Registers Objective Questions

Electronic Devices & Circuits Objective Questions

Electronic Devices & Circuits Quiz – Set 8

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?