Why we use Negative Voltage in Vibration Measurement ?

An Excellent Answer by Bently Nevada Employee:

As a 20-year Bently Nevada employee, and as someone responsible for answering such questions over the years within our company as well as externally, allow me to explain the rather interesting circumstances behind the use of negative voltages (-24 vdc) for powering eddy current vibration oscillator/demodulator devices. I will then proceed to explain the operating principles behind the eddy current proximity probe and how it converts physical gap between the probe and its target into a voltage.

First, the question of negative voltage. The short answer is that When Don Bently worked on making solid-state versions of the eddy-current measurement system (it was actually originally designed in the 1930s by GE engineers using vacuum tubes), he had a choice between using N-P-N transistors or P-N-P transistors. At the time, transistors were quite expensive, so he chose the least expensive of the two: P-N-P (apparently, PNP transistors they were less expensive to manufacture 50 years ago than their NPN counterparts).

Because the circuits used PNP transistors, a negative bias voltage was required rather than a positive bias voltage. Don chose -18V. This was later changed to -24V to allow more linear range from the transducer.

At that time, the industrial instrumentation community had not yet standardized on +24 vdc, and by the time they did, there were so many Bently Nevada eddy current vibration sensors installed that changing to +24V rather than -24V was not greeting with enthusiasm by users. Hence, it has remained -24V to this day.

This was not a deliberate effort to “be different” or “non-conformist” on the part of Bently Nevada. It was quite literally based on which components were the least expensive when the technology was originally introduced 50-plus years ago.

Now, the question of how an eddy-current proximity probe works:

An eddy-current probe works by passing an alternating current through a coil of wire and measuring the coil’s impedance. This impedance changes when the probe is brought near an electrically conductive material and the impedance change is proportional to the physical gap between the coil and the conductive target. The sensing electronics in turn convert this impedance change to a voltage, providing an electrical output directly proportional to physical gap which is directly proportional to vibration.

Also Read: Vibration Sensors Principles & Types

You've successfully subscribed !

View Comments

Share

Recent Articles

Batch Mixing with PLC Ladder Logic Program
  • PLC Tutorials

Batch Mixing with PLC Ladder Logic Program

In this example, we will learn batch mixing with PLC ladder logic program using timer…

1 week ago
  • PLC Tutorials

PLC Example on Manufacturing Line Assembly

This PLC example on manufacturing line assembly is an intermediate-level PLC program prepared for the…

2 weeks ago
  • PLC Tutorials

PLC Programming Example with Pushbutton and Motor

In this article, you will learn the PLC programming example with pushbutton and motor control…

3 weeks ago
  • PLC Tutorials

Boolean Logic to PLC Programming

This article teaches how to convert Boolean logic to PLC programming ladder logic with the…

4 weeks ago
  • PLC Tutorials

PLC Programming Example on Timers Function Block

In this article, you will learn the PLC programming example on timers function block using…

3 weeks ago
  • PLC Tutorials

PLC Pump Control: 10 seconds ON & 20 seconds OFF

Design a program for PLC pump control such that the pump must be turned ON…

2 weeks ago