Categories: Power Electronics

Turning Off SCR – Commutation

  • To tum on a thyristor, a low voltage, short duration pulse is applied to the gate (typically 4V, 100µs).
  • Once the thyristor is turned-on, the gate loses control and the thyristor will only turn off when the load current falls virtually to zero, or the thyristor is reverse biased.
  • The thyristor will turn off naturally with a.c. supplies as the voltage reverses (which is called as Natural Commutation), but no such reversal occurs with d.c. supplies and it is necessary to force a voltage reversal if tum-off is to occur. This process is called Forced Commutation. This post will give you a brief introduction about SCR commutation.

VI characteristics of SCR

Commutation:

The process of turning OFF SCR is defined as “Commutation”.

  • In all commutation techniques, a reverse voltage is applied across the thyristor during the turn OFF process.
  • By turning OFF a thyristor we bring it from forward conducting to the forward blocking mode.
  • The condition to be satisfied in order to turn OFF an SCR are:
    1. IA < IH ( Anode current must be less than holding current)
    2. A reverse voltage is applied to SCR for sufficient time enabling it to recover its blocking state.
  • There are two methods by which a thyristor can be turned OFF.
    1. Natural Commutation
    2. Forced Commutation

Natural Commutation:-

  • In AC circuit, the current always passes through zero for every half cycle.
  • As the current passes through natural zero, a reverse Voltage will simultaneously appear across the device.
  • This will turn OFF the device immediately.
  • This process is called as natural commutation, since no external circuit is required for this purpose.

Forced Commutation:

  • To turn OFF a thyristor, the forward anode current should be brought to zero for sufficient time to allow the removal of charged carriers.
  • In case of DC circuits the forward current should be forced to zero by means of some external circuits.
  • This process is called as forced commutation
You've successfully subscribed !
Share

Recent Articles

  • PLC Tutorials

Example PLC Program to Control a Pump based on Level Sensors

Learn an example PLC program to control a pump based on level sensors using ladder…

2 weeks ago
  • PLC Tutorials

PLC Timer Application in Security Camera Recording

In the PLC timer application for security camera recording, when motion is detected then camera…

2 weeks ago
  • PLC Tutorials

Batch Mixing with PLC Ladder Logic Program

In this example, we will learn batch mixing with PLC ladder logic program using timer…

2 weeks ago
  • PLC Tutorials

PLC Example on Manufacturing Line Assembly

This PLC example on manufacturing line assembly is an intermediate-level PLC program prepared for the…

2 weeks ago
  • PLC Tutorials

PLC Programming Example with Pushbutton and Motor

In this article, you will learn the PLC programming example with pushbutton and motor control…

3 weeks ago
  • PLC Tutorials

Boolean Logic to PLC Programming

This article teaches how to convert Boolean logic to PLC programming ladder logic with the…

1 month ago