Multiple Choice Questions

Split-Range, Auto-Selector, Ratio & Cascade Systems

Split-Range Control System Questions, Auto-Selector Questions, Ratio Control System Questions & Cascade Control System Questions.

1. An auto-selector control system should be considered when

a. The process has more controlled variables than manipulated variables
b. The process has more manipulated variables than controlled variables
c. Two independent control systems are Dot economical
d. Two or more measured variables must be isolated

Answer: a

2. The auto-selector controller will function only when the measurement inputs are:

a. Interdependent
b. Independent
c. Isolated from one another
d. Flow measurements

Answer: a

3. The ratio controller

a. Can be used with any combination of related process variables
b. Has one measurement in put and two outputs
c. Can be used for even-numbered ratios
d. Must always employ the derivative mode in the controller

Answer: a

4. Two flows are to be ratio controlled, the first is measured with an orifice and the second with a shedding vortex flowmeter. The signals must be:

a. Both made linear by using a square root extractor on the orifice signal
b. Used as if a 1 percent error can be tolerated
c. Both made linear by using a square root extractor on the shedding vortex transmitter
d. Flow-calibrated

Answer: a

5. A cascade control system will increase the natural frequency of the control loop along with having the following inftuence on the magnitudes of the associated time constants

a. Reduce them
b. Increase them
c. Not affect them
d. Have an unpredictable effect

Answer: a

6. In a cascade control system the secondary may be regarded as:

a. A valve actuator
b. An elaborate final control element
c. A means of slowing down regulation of the manipulated variable
d. A sophisticated noise filter

Answer: b

7. If two square root flow signals are to be ratio-controlled and the ratio factor adjusted, the maximum practical factor is:

a. 0.6 to 1.7
b. 0.3 to 3.0
c. 1.0 to 10
d. 1.0 to 1.0

Answer: b

8. A very common secondary loop that may be used with almost any process except flow is:

a. Flow
b. Temperature
c. Pressure
d. Valve position

Answer: a

9. A cascade control system is to be adjusted. You should first

a. Place the primary controller on manual and adjust the secondary controller
b. Place the secondary controller on manual and adjust the primary controller
c. Place both controllers on automatic and go through the conventional adjustment routine
d. Bypass the secondary controller and adjust the primary controller by the conventional method

Answer: a

10. If the time constant of the secondary loop is greater than the time constant of the primary loop, cascade control will:

a. Shorten the period of the total system
b. Lengthen the period of the total system
c. Improve the operation of the system
d. Provide no benefits

Answer: d

11. A duplex controller has the following number of inputs:

a. One
b. Two
c. One for each output
d. As many as required

Answer: a

12. The duplex controller provides the following number of control valve signals:

a. One
b. Two
c. One for each output
d. As many as required

Answer: b

You've successfully subscribed !
Share

Recent Articles

Electrical Drives – Modes, Types, Speed Control Applications
  • Electrical Basics

Electrical Drives – Modes, Types, Speed Control Applications

Electrical Drives control the motion of electric motors. Motion control is required in industrial and…

4 days ago
  • PLC Tutorials

PLC Ladder Logic Design: Control 3 Motors with Toggle Switch

PLC ladder logic design to control 3 motors with toggle switch and explain the program…

3 weeks ago
  • PLC Tutorials

VFD Simulator Download – Free Yaskawa V1000 Software

VFD simulator download: Master the online tool from the Yaskawa V1000 & programming software for…

4 days ago
  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

1 week ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

1 week ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

1 week ago