Multiple Choice Questions

Parameter Optimization

Parameter Optimization

1. A conditionally stable system exhibits poor stability at :

a) Low frequencies
b) Reduced values of open loop gain
c) Increased values of open loop gain
d) High frequencies

Answer: b

Explanation: A conditionally stable system is the system which is stable only for certain values of K and exhibits poor stability at the reduced values of open loop gain.

2. The type 0 system has ______ at the origin.

a) No pole
b) Net pole
c) Simple pole
d) Two poles

Answer: a

Explanation: The type of the system is defined as the property of the system which has pole at the origin.

3. The type 1 system has ______ at the origin.

a) No pole
b) Net pole
c) Simple pole
d) Two poles

Answer: c

Explanation: The type of the system is defined as the pole at the zero and type 1 is defined as the 1 pole at the origin.

4. The type 2 system has at the origin.

a) No net pole
b) Net pole
c) Simple pole
d) Two poles

Answer: d

Explanation: Type of the system is defined as the number of pole at origin and type 2 is the 2 poles at the origin.

5. The position and velocity errors of a type-2 system are :

a) Constant, constant
b) Constant, infinity
c) Zero, constant
d) Zero, zero

Answer: c

Explanation: The position and velocity error of the type 2 system is zero and a constant value as for type 2 system velocity error is finite while acceleration error is infinite.

6. Velocity error constant of a system is measured when the input to the system is unit _______ function.

a) Parabolic
b) Ramp
c) Impulse
d) Step

Answer: b

Explanation: Velocity error constant of a system is measured when the input to the system is unit ramp function then only velocity error is finite but error due to other inputs are not defined.

7. In case of type-1 system steady state acceleration is :

a) Unity
b) Infinity
c) Zero
d) 10

Answer: b

Explanation: In case of type-1 system steady state acceleration is infinity as for the type less than 3 acceleration is not defined it is infinity.

8. If a step function is applied to the input of a system and the output remains below a certain level for all the time, the system is :

a) Not necessarily stable
b) Stable
c) Unstable
d) Always unstable

Answer: a

Explanation: If the input is bounded and output is also bounded then the system is always stable and step input is bounded and the output is always under certain li its then the system is stable.

9. Which of the following is the best method for determining the stability and transient response?

a) Root locus
b) Bode plot
c) Nyquist plot
d) None of the mentioned

Answer: a

Explanation: Root locus is the best method for determining stability of the transient response as it gives the exact pole zero location and also their effect on the response.

10. Phase margin of a system is used to specify which of the following?

a) Frequency response
b) Absolute stability
c) Relative
d) Conditional stability

Answer: b

Explanation: Phase margin of the system can be used for determining the absolute stability of the system.

You've successfully subscribed !
Share

Recent Articles

PLC Example on Manufacturing Line Assembly
  • PLC Tutorials

PLC Example on Manufacturing Line Assembly

This PLC example on manufacturing line assembly is an intermediate-level PLC program prepared for the…

2 weeks ago
  • PLC Tutorials

PLC Programming Example with Pushbutton and Motor

In this article, you will learn the PLC programming example with pushbutton and motor control…

2 weeks ago
  • PLC Tutorials

Boolean Logic to PLC Programming

This article teaches how to convert Boolean logic to PLC programming ladder logic with the…

4 weeks ago
  • PLC Tutorials

PLC Programming Example on Timers Function Block

In this article, you will learn the PLC programming example on timers function block using…

3 weeks ago
  • PLC Tutorials

PLC Pump Control: 10 seconds ON & 20 seconds OFF

Design a program for PLC pump control such that the pump must be turned ON…

2 weeks ago
  • Common

Polyvinyl Alcohol in Oil Field

Polyvinyl alcohol (PVA) is a water-soluble and biodegradable synthetic polymer used in oil field cementing…

2 days ago