Multiple Choice Questions

Linearizing Effect & Regenerative Feedback MCQ

Linearizing Effect & Regenerative Feedback

1. The effect of adding feedback makes the system__________

a) Linear
b) Non-linear
c) Time variant
d) Time invariant

Answer: a

Explanation: Consider the single loop system with forward path transfer function as the square function then the response generated is nonlinear if system is open loop but will be approximately linear if closed loop.

2. The relation between output response and input signal in closed loop system is :

a) Exponential
b) Parabolic
c) Linear
d) Nonlinear

Answer: c

Explanation: Due to the linearizing effect of the feedback the relation between output response and the input signal in closed loop system is linear.

3. Assertion (A): Practical systems must be closed loop system.
Reason (R): This is due to the fact that closed loop systems are least affected by parameter variations, stable, higher bandwidth, linear and more speed of response.

a) Both A and R are true and R is the correct explanation of A.
b) Both A and R are true but R is not the correct explanation of A.
c) A is true but R is false.
d) A is false but R is true.

Answer: a

Explanation: Practically systems used must be linear to avoid error, ease of calibration and also to get accurate results but the systems used are non-linear to avoid the error due to the linearity they are approximated.

4. Regenerative feedback is also called as_________________

a) Negative feedback
b) Positive feedback
c) No feedback
d) Negative and Positive Feedback

Answer: b

Explanation: As the name implies that is regenerates the oscillations hence by name it can be positive.

5. Which of the following are the characteristics of regenerative feedback:

a) Zero damping
b) Stable
c) Least sensitive to parameter variations
d) None of the mentioned

Answer: a

Explanation: Output response is slow and sluggish and transient time is more due to the oscillations.

6. Which of the following are true:

a) Sensitivity of regenerative feedback is more than negative feedback but less than non-feedback system
b) Sensitivity of regenerative feedback is more non-feedback system but less than negative feedback system
c) Sensitivity of regenerative feedback is less than both
d) Sensitivity of regenerative feedback is more than both

Answer: c

Explanation: Sensitivity of the positive feedback system is even more than non-feedback system and it is more by a factor of 1/1-GH.

7. Loop gain provided by the regenerative feedback makes the closed loop transfer function insensitive to G(s).

a) True
b) False

Answer: a

Explanation: As if the positive feedback loop gain is nearly considered to be unity then transfer function becomes insensitive to G(s).

8. Which of the following statements is correct for any closed loop system?

a) All the co-efficient can have zero value
b) All the co-efficient are always non-zero
c) Only one of the static error co-efficient has a finite non-zero value
d) None of the mentioned

Answer: c

Explanation: Closed loop systems are the systems with positive and negative feedback and for standard test signals error constants are defined and for one of the inputs one of the static error co-efficient has a finite non-zero value.

You've successfully subscribed !
Share

Recent Articles

PLC Ladder Logic Design: Control 3 Motors with Toggle Switch
  • PLC Tutorials

PLC Ladder Logic Design: Control 3 Motors with Toggle Switch

PLC ladder logic design to control 3 motors with toggle switch and explain the program…

3 weeks ago
  • PLC Tutorials

VFD Simulator Download – Free Yaskawa V1000 Software

VFD simulator download: Master the online tool from the Yaskawa V1000 & programming software for…

3 days ago
  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

6 days ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

7 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

7 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

4 days ago