Multiple Choice Questions

Direct Method & Constructing of Liapunov for the Linear & Non-Linear System

Direct Method & Constructing of Liapunov for the Linear & Non-Linear System

1. If the Liapunov’s function cannot be found then the system is:

a) Stable
b) Unstable
c) Conditionally stable
d) Marginally stable

Answer: b

Explanation: It is very difficult to find the Liapunov’s function and several techniques are devised for the same and if the Liapunov’s function is not available then the system is unstable.

2. Liapunov’s stability analysis is for the :

a) LTI system
b) Time variant system
c) Non-linear system
d) Linear system

Answer: c

Explanation: Liapunov’s stability criterion is for the non-linear system.

3. The system is unstable for:

a) W (x)>0; x not equal to zero
b) W (0) =0
c) W (x) has continuous partial derivative with respect to all components of x
d) All of the mentioned

Answer: d

Explanation: It requires much ingenuity of devise a suitable W function to devise a Liapunov function V. In stability analysis of nonlinear systems, it is valuable to establish conditions for which the system is unstable.

4. Liapunov’s stability for non-linear system is same as the Routh Hurwitz criteria for the linear system.

a) True
b) False

Answer: a

Explanation: Liapunov stability is similar in function as the Routh Hurwitz criteria and Silvester’s theorem can be used to prove it.

5. Conditions of ___________ are necessary and sufficient condition for the asymptotic stability of the system.

a) Linear system
b) Krasovskii’s method
c) positive definiteness
d) Variable gradient method

Answer: c

Explanation: For the system to be asymptotic stable which is desired for the Liapunov stability positive definiteness of the system must be fulfilled.

6. It is difficult to form Liapunov’s function for:

a) Linear system
b) Non-linear
c) Time variant systems
d) Time –invariant systems

Answer: b

Explanation: For non-linear system it is difficult to form the Liapunov’s function And we use various method to do this.

7. If the V is positive definite, for the system to be asymptotically stable, Q should be negative definite.

a) Krasovskii’s method
b) Variable gradient method
c) Constant method
d) Non-variable gradient method

Answer: a

Explanation: If the V is positive definite, for the system to be asymptotically stable, Q should be negative definite. For Krasovskii’s method and in addition V should tend to infinity and the system is asymptotically stable in-the large.

8. The method which provides considerable flexibility in finding the Liapunov’s function is:

a) Krasovskii’s method
b) Variable gradient method
c) Constant method
d) Non-variable gradient method

Answer: b

Explanation: Variable gradient method provides considerable flexibility in finding the Liapunov’s function as the quadratic form approach is too restrictive.

9. Liapunov stability analysis is different from the classical theories approach of stability.

a) True
b) False

Answer: a

Explanation: Liapunov’s stability theorem is applied for the non-linear systems but other stability theorems are applied for the linear systems.

10. For non-linear systems the equation for damping factor as in linear system is called _________

a) Krasovskii’s equation
b) Vander Pol’s equation
c) Constant method
d) Non-variable gradient equation

Answer: b

Explanation: For non-linear systems the equation for damping factor as in linear system is called Vander pol’s equation which depends upon x and damping factor has large positive values for this.

You've successfully subscribed !
Share

Recent Articles

PLC Ladder Logic Design: Control 3 Motors with Toggle Switch
  • PLC Tutorials

PLC Ladder Logic Design: Control 3 Motors with Toggle Switch

PLC ladder logic design to control 3 motors with toggle switch and explain the program…

3 weeks ago
  • PLC Tutorials

VFD Simulator Download – Free Yaskawa V1000 Software

VFD simulator download: Master the online tool from the Yaskawa V1000 & programming software for…

3 days ago
  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

6 days ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

6 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

6 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

4 days ago