Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Difference Between RCCB and MCCB
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > Difference Between RCCB and MCCB

Difference Between RCCB and MCCB

In this post, we will learn the difference between RCCB and MCCB circuit breakers which are widely used in electrical circuits.

Last updated: November 17, 2022 3:02 pm
Viral Nagda
Electrical Basics
5 Comments
Share
4 Min Read
SHARE

In this post, we will learn the difference between RCCB and MCCB.

Circuit breakers are an essential part of an electrical circuit. It is a device that is used as a protective switch for passing electrical current with tripping conditions checked.

When it detects a trip condition, the breaker opens its contact and isolates the input and output voltage from contacting each other.

Many types of circuit breakers are used in a circuit; but in this post, we will focus on two of the most used ones – RCCB and MCCB. We will discuss the difference between both of them in this post.

Difference Between RCCB and MCCB

Difference Between RCCB and MCCB

Many get confused in its naming convention and consider both of them as equal. But, there are considerable differences between them.

  • RCCB stands for Residual Current Circuit Breaker and MCCB stands for Moulded Case Circuit Breaker.  
  • MCCB is used to protect against overload and short-circuiting. But, RCCB is used to protect against earth leakage fault current. Many do not know the exact meaning of earth leakage fault; let us understand it first. In a normal circuit, line and neutral currents will always be equal and balanced. But, whenever there is an earth leakage, as the leakage current flows through the earth, there will be an imbalance in both these currents as the line current will be higher than the neutral current. This difference in current is called residual current.
  • MCCB is available in higher current ratings (up to 2500A) as compared to RCCB which has smaller current ratings, typically up to 160A.
  • The construction of MCCB consists of a body, incoming terminal, magnetic coil, bimetal strip, arc chute, copper braid, and operator on-off handle. The construction of RCCB consists of CBCT (core balanced current transformer), magnetic relay coil, incoming and outgoing terminal, and tripping mechanism.
  • Cost-wise, MCCB is cheaper than RCCB.
  • There is less disturbance in the tripping mechanism in MCCB than in RCCB. This is because some sudden load changes, small or big, can cause an instant change in the difference of line and neutral currents. RCCB detects this change and trips the circuit. So, RCCB is sensitive to frequent load current changes.
  • MCCB does not provide protection against electric shocks to humans, but RCCB provides protection against electric shocks. This is because the role of RCCB is primarily to detect earth leakage and trip the circuit when detected. Earth leakage is dangerous for the human body. Typically, the human body can withstand a shock of 30mA. After this, it can lead to paralysis or even death for weaker human hearts. And, earth leakage current typically starts from 10mA and can go beyond 30mA.
  • MCCB is available in single-pole, two-pole, three-pole, and four-pole versions. But, RCCB has only two-pole, three-pole, and four-pole variants.
  • There is no test circuit operation in MCCB, but RCCB has a test circuit operation for checking if it’s working.

These are the differences between RCCB and MCCB. It must be up to the electrical engineer to decide what to choose if he knows the basic requirements and functions.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

What is an Electrical Conduit? – Types – How to Choose?
Difference Between Earth and Neutral
What is Variable Air Volume Controller in HVAC?
What is a Power Transformer? – Components and Types
Totally Enclosed Fan Cooled (TEFC) Motors Rampant Winding Burnouts
Lightning Arrester Basics and Terminology
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
5 Comments
  • Anil says:
    July 24, 2022 at 10:16 pm

    Nice and handy information

    Reply
  • Maitrey Nandola says:
    July 25, 2022 at 8:21 am

    Nice written to understand easily.

    Reply
  • Gunjan Kumar says:
    July 25, 2022 at 9:46 am

    Interesting

    Reply
  • Ramesh Chand says:
    February 25, 2023 at 5:04 pm

    Thankyou sir

    Reply
  • Ahmed Morsy says:
    June 7, 2023 at 8:49 pm

    Very nice written

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Basics of Star and Delta connections
Top Electrical Engineering Questions & Answers
What is an Electrical Drive? Types, Advantages, Disadvantages
Most Asked Questions on Servo Motor (Answers)
Motor VFD Drive features
Difference Between Alternator and Generator?
Proper Sizing of Conductors
Motor Control Circuit Wiring
DOL Starter – Working, Circuit, Advantages, Disadvantages, Applications
How to Connect a 3 Phase Motor in Star and Delta Connections?

Keep Learning

Why CT Secondary Should Never Be Kept Open?

Why CT Secondary Should Never Be Kept Open?

Group of Induction Motors

How to Operate a Group of Induction Motors using PLC Logic?

What is insulation

What is insulation? How to Choose the Insulation Material?

What is a Multi-Core Cable

Difference Between Single Core and Multi-Core Cables

What is ELCB

What is ELCB? Principle, Advantages, Disadvantages, Applications

Control Methods in Servo Motor Drives

Various Control Methods in Servo Motor Drives

Bonding and Grounding Electrical Systems

Testing and Inspection of Bonding and Grounding Systems

Automatic Transfer Switch

Automatic Transfer Switch (ATS) Using Classic Control Circuit

Discover More

Stability in Frequency Domain

Mathematical Preliminaries

DC Circuit Node Equations

DC Circuit Analysis Node Equations

Difference Between the Control Valve and Shut-off Valve

Difference Between the Control Valve and Shut-off Valve

Transformer Operation Under No-Load

Transformer Operation Under No-Load

Vortex Flow Meter Principle

Vortex Flow meter Animation

AC Fundamentals Objective Questions and Answers

AC Fundamentals Objective Questions and Answers

Side Mounting Float Switch Working Principle

Side Mounting Float Switch Working Principle

InTouch SCADA Training Course

Free InTouch SCADA Tutorial Course for Beginners

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?