Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Effect of Adding a Zero to a System
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Effect of Adding a Zero to a System

Effect of Adding a Zero to a System

Last updated: November 27, 2021 5:41 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Effect of Adding a Zero to a System

1. Assertion (A): The zeroes on the real axis near the origin are generally avoided in design.
Reason (R): In a sluggish system introduction of zeroes can improve the transient response

a) Both A and R are true and R is correct explanation of A
b) Both A and R are true but R is not correct explanation of A
c) A is true but R is false
d) A is false but R is true

Answer: b

Explanation: Zero is defined as the root of the numerator of the transfer function and zero is to introduce a pronounced peak to the system’s response whereby the peak overshoot may increase appreciably.

2. Addition of zero increases the stability.

a) True
b) False

Answer: a

Explanation: Zero is defined as the root of the numerator of the transfer function and addition of zeroes increases the stability as the speed of response increases.

3. Zeroes are defined as:

a) Roots of the denominator of the closed loop transfer function
b) Roots of the numerator of the closed loop transfer function
c) Parts of the numerator
d) Parts of the denominator

Answer: b

Explanation: Zeroes are the roots of the numerator of the closed loop system and addition of the zeroes increases the stability of the closed loop system.

4. As zero moves sufficiently left from the origin the effect of zero becomes less pronounced.

a) True
b) False

Answer: a

Explanation: The effect of zero on transient response will be negligible if the zero moves left from the origin as the zero which is nearer to the origin is more dominant.

5. If number of poles are greater than number of zeroes then the system is known as ______________

a) Stable system
b) Unstable system
c) Minimum phase system
d) Non-minimum phase system

Answer: c

Explanation: Minimum phase system is defined as the perfect system with zeroes greater than poles and also the zeroes and poles lying on the left half of the s plane entirely.

6. A control system is generally met with the time response specifications:

a) Steady state accuracy
b) Damping factor
c) Setting time
d) All of the mentioned

Answer: d

Explanation: Steady state error, damping factor and settling times are the specifications are needed to control the system’s stability and speed of response.

7. Steady state accuracy specified in terms of:

a) Steady state error
b) Damping ratio
c) Natural frequency
d) All of the mentioned

Answer: a

Explanation: Steady state accuracy entirely depends on the accuracy of steady state which is determined by steady state error which is the difference between the final output and desired output.

8. Steady state accuracy is determined by suitable choice of____________

a) Steady error
b) Error constants
c) Damping
d) Transient error

Answer: b

Explanation: Steady state accuracy is determined by suitable choice of error constants Kv, Kp and Ka depending upon the type of the system.

9. Damping factor specifies:

a) Peak overshot to step input.
b) Steady state error
c) Damping ratio
d) Natural frequency

Answer: a

Explanation: Maximum peak overshoot is the maximum peak of the transient response at the resonant frequency and is so calculated as to determine the value of damping factor.

10. If rise time is also taken into consideration it should be ____________ to the settling time.

a) Inconsistent
b) Consistent
c) Perfect
d) Unique

Answer: b

Explanation: Rise time and settling time determine the speed of response as if the values of both these if less then the speed of response will be more and both of these depend on the damping factor and natural frequency.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Optimal Control Problems – Part 1
Flow Measurement Multiple Choice Questions
Electron Spin Resonance
Instrumentation for Electron Spectroscopy
Top 1000 Analytical Instrumentation Questions & Answers
Operation of Chromatography Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Construction of Phase -Trajectories
Instrumentation of Ion Spectroscopy
pH Meters Questions & Answers
Realization of Basic Compensators
Feedforward Control Questions and Answers
Instrument Calibration Multiple Choice Questions
Necessary Conditions for Stability & Non-Linear Systems
Absorption Instrumentation Questions & Answers
Signal Reconstruction
Detection System of Gas Chromatography Questions and Answers

Keep Learning

Radiochemical Questions and Answers

Liquid Scintillation Counters Questions & Answers

Optimal Control Systems

The Infinite Time Regulator Problem

Time Response Analysis

Effect of Adding a Zero to a System – II

Root Locus Concepts Objective Questions

Root Locus in Control Systems

Instrumentation Diagrams Multiple Choice Questions

Instrumentation Diagrams Multiple Choice Questions

Flow Measurement Questions

MCQ on Flow Measurement

Stability in Frequency Domain

Time Domain Analysis

Mass Spectrometer Questions and Answers

Surface Spectroscopic Techniques

Discover More

Lift check valves

What is Lift Check Valve ?

VFD Interview Questions and Answers

VFD Interview Questions and Answers – Electrical Drives

Location of Measurement Displays

Location of Measurement Displays

Thermowell Immersion Length

Thermowell Insertion and Immersion Length

Top Non-PLC Certification Courses for Automation Professionals

Top Non-PLC Certification Courses for Automation Professionals

Mass Spectrometer Questions and Answers

Inductively Coupled Plasma Mass Spectrometer

Choke Valve Hydro Test Setup

Choke Valve Hydro Testing Procedure

Certified Control Systems Technician (CCST) Sample Questions

Certified Control Systems Technician (CCST) Questions

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?