Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Steady-state Errors & Error Constants
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Steady-state Errors & Error Constants

Steady-state Errors & Error Constants

Last updated: November 27, 2021 5:41 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Steady-state Errors & Error Constants

1. The steady state error for a unity feedback system for the input r(t) = Rt^2/2 to the system G(s) = K(s+2)/s(s3+7s2+12s) is

a) 0
b) 6R/K
c) ∞
d) 3R/K

Answer: b

Explanation: Ka = 2K/12 = K/6
Ess = 6R/K.

2. A control system is operated with a parabolic input as shown below

If Ka is static error constant of the system, then its dynamic error constant K2 is

a) 0.01
b) 0.02
c) 0.03
d) 0.04

Answer: b

Explanation: Ka = 100/(s+2)
K2 = 1/50 = 0.02.

3. Find the velocity error constant of the system given below :

a) 0
b) 2
c) 4
d) ∞

Answer: c

Explanation: Comparing with the characteristic equation the values of G and w are calculated as G = 1 and w = 4 and hence the system is critically damped.

4. Consider the unity feedback system with open loop transfer function the minimum value of the steady state error to a ramp input r(t) = 6tu(t) is OLTF = K/s(s+1)(s+2)

a) 1
b) 2
c) 3
d) 4

Answer: b

Explanation: Routh-Hurwitz criterion is used to calculate the stability of the system by checking the sign changes of the first row and from Routh-Hurwitz criterion maximum value of K = 6 ess = A/Kv for type-1 system and A = 6then for Kv = K/2, ess = 2.

5. A ramp input applied to a unity feedback system results in 5% steady state error. The type number and zero frequency gain of the system are respectively

a) 1 and 20
b) 0 and 20
c) 0 and 1/20
d) 1 and 1/20

Answer: a

Explanation: Steady state error is the error calculated between the final output and desired output and for the good control system the error must be less and this steady state error is inversely proportional to gain.

6. A particular control system yielded a steady state error of 0.20 for unit step input. A unit integrator is cascaded to this system and unit ramp input is applied to this modified system. What is the value of steady-state error for this modified system?

a) 0.10
b) 0.15
c) 0.20
d) 0.25

Answer: d

Explanation: The integrator is similar to the phase lag systems and it is used to reduce or eliminate the steady state error and when it is cascaded with the ramp input hence the acceleration error constant is calculated which is equal to 0.25.

7. The error constants described are the ability to reduce the steady state errors.

a) True
b) False

Answer: a

Explanation: As the type of the system becomes higher more steady state errors are eliminated.

8. Systems of type higher than 2 are not employed in practice.

a) True
b) False

Answer: a

Explanation: These are more difficult to stabilize and dynamic errors are much larger.

9. Steady state refers to

a) Error at the steady state
b) Error at the transient state
c) Error at both state
d) Precision

Answer: a

Explanation: Steady state errors are the change in the output at the steady state with respect to the change in the input.

10. The disadvantages of the error constants are:

a) They do not give the information of the steady state error when the inputs are other than the three basic types
b) Error constant fail to indicate the exact manner in which the error function change with time.
c) They do not give information of the steady state error and fail to indicate the exact manner in which the error function change with time
d) They give information of the steady state error

Answer: c

Explanation: The disadvantages of the error constants are as they do not give the information of the steady state error when the inputs are other than the three basic types and error constant fail to indicate the exact manner in which the error function change with time.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Controller Components – Part 1 Objective Questions
Ion Analyzer Questions & Answers
Analytical Measurement Multiple Choice Questions
Liapunov’s Stability Criterion – Part II
Stepper Motor MCQ
Concept of Stability in Control Systems
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Controllability & Observability
Permit to Work System Online Test
Control Systems Multiple Choice Questions
Spectral Method of Analysis Questions & Answers
Fuzzy Logic Control
PLC Interview Questions and Answers
Absorption Instrumentation Questions & Answers
Optimal Control Problems – Part 2
Instrumentation for Electron Spectroscopy
Flow Measurement Multiple Choice Questions

Keep Learning

Feedback Characteristics of Control Systems

Linearizing Effect & Regenerative Feedback MCQ

Liapunov’s Stability Analysis

Direct Method & Constructing of Liapunov for the Linear & Non-Linear System

Objective Questions of Building Fire and Gas Detectors

Objective Questions of Building Fire and Gas Detectors

Top 100 Control Systems Objective Questions & Answers

Top 100 Control Systems Objective Questions & Answers

Spectrometers Questions and Answers

X-Ray Diffractometers Questions & Answers

Flow Measurement Questions

MCQ on Flow Measurement

Analyzers Questions and Answers

Dissolved Oxygen Analyzer Questions and Answers

Nuclear Magnetic Resonance Spectrometer Questions and Answers

Types of NMR Spectrometers Questions & Answers

Discover More

Pollution Monitoring Instruments Questions and Answers

Carbon Monoxide Questions & Answers

Closed Tank Remote Seal Level Transmitter calculation

Remote Seal Transmitters Ranging Calculation

Strain Gauge Bridge Circuit

Something is Wrong with Strain Gauge Bridge Circuit

Analyzers Questions and Answers

Paramagnetic Oxygen Analyzers Questions & Answers

H & B Gas Analyzer Principle and Calibration Procedure

Siemens Tia Portal PLC Training Course

Siemens Tia Portal PLC Training Course

Calculate Temperature of RTD

Calculate Temperature of RTD

PID Controller Tuning

How to tune a PID Controller ?

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?