Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Feedback Control Loop Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Feedback Control Loop Questions & Answers

Feedback Control Loop Questions & Answers

Last updated: November 27, 2021 5:36 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Feedback Control Loop Questions & Answers

1. With adequate gain and inphase feedback any system will:

a. Drift
b. Oscillate
c. Increase amplitude
d. Degenerate

Answer: b

2. The natural frequency at which a closed-loop system will cycle depends upon:

a. The amplifier gain
b. The attenuation provided by the process
c. The phase shift provided by the resistance-capacitance and dead time networks that exist in the system
d. Resonance

Answer: c

3. The Bode diagram describes:

a. Gain and phase shift through the usable frequency range
b. The system’s linearity
c. The reaction to a step change
d. The recovery curve that will result from a load change

Answer: a

4. All systems may be assumed to be:

a. Linear
b. Nonlinear
c. Linear for the purpose of initial consideration but with full knowledge that this may not be the case
d. Nonlinear for purposes of analysis with the exception that the system may prove to be linear

Answer: c

5. A closed-loop control system that employs a three-mode controller:

a. Can oscillate or cycle at only one frequency
b. Can oscillate or cycle at several frequencies. depending on controller adjustment
c. Will not oscillate because of the stability provided by derivative
d. Will produce only damped oscillations with a 0.25 damping ratio

Answer: b

6. We have a closed-loop control system which is cycling. We should:

a. Increase the proportional band
b. Increase integral action
c. Check and adjust both
d. Immediately shut it down

Answer: c

7. A proportional controller is being used to control a process and the offset between set point and control point must be held to a minimum. This would dictate that the proportional band

a. Be as narrow as possible
b. Be as wide as possible
c. Be of moderate value
d. Does not relate to the problem

Answer: a

8. The system gain of the closed-loop control system:

a. Refers to the process gain
b. Refers to the gain of the measurement and control devices
c. Refers to the total gain of all components. including measurement, controller, valve operator, valve, and process
d. Relates only to the gain of the controller

Answer: b

9. If a closed-loop control system employs a straight proportional controller and is under good control. offset:

a. Will vary in magnitude
b. Will not exceed one-half of the proportional bandwidth
c. Will exceed the deviation
d. Is repeated with each reset

Answer: b

10. Any closed-loop system with in-phase feedback and a gain of one or more will:

a. Degenerate
b. Cycle or oscillate
c. Exhibit a 0.25 damping ratio
d. Produce square waves

Answer: b

11. If a closed-loop control system is adjusted to produce a 0.25 damping ratio when subjected to a step change, the system gain is:

a. 0.1
b. 0.25
c. 0.5
d. 1.0

Answer: c

12. A straight proportional controller is employed to control a process of Narrowing the proportional band will:

a. Not change the offset
b. Decrease the offset
c. Always cause cycling
d. Never cause cycling

Answer: b

13. The type of process that most often can benefit from derivative is:

a. Flow
b. Level
c. Temperature
d. Pressure

Answer: c

14. Pure dead time in a process contributes a gain or:

a. Zero
b. Infinite
c. Depends upon dynamics
d. One

Answer: d

15. Referring to Figure, the transmitter span is 200 °F; the controller proportional band is adjusted to 150 percent; the equal percentage valve delivers saturated steam containing 40,000 Btu per minute at full open; and water enters the exchanger at 50°F and is heated to 200 DegF at a 40 gpm maximum flow rate. The static gain of this control loop is approximately:

Instrumentation MCQ

Fig : Responsec haracteristicso Ce ache lementi n a Ceedbaccko ntrolloop-heat, exchangepr rocesso

a. 0.5
b. 1.0
c. 1.5
d. 2.0

Answer: a

16. The integral control mode is:

a. Phase-Ieading
b. Phase-Iagging
c. Inphase
d. Phase-reversing

Answer: b

17. The derivative control mode is

a. Phase-Ieading
b. Phase-Iagging
c. Inphase
d. Phase-reversing

Answer: a

18. The most common combination of control modes found in the typical process plant is:

a. Proportional-only
b. Proportional, integral, and derivative
c. Proportional-plus-integral
d. On/off

Answer: c

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Effect of Adding a Zero to a System
UV Visible Spectrometers Questions and Answers
Programmable Logic Controllers Multiple Choice Questions
Robotic Control System – Part II
Stability of Nonlinear System – II
Tuning of PID Controllers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Chromatography Questions & Answers
State Variable Analysis – Part II
Top 1000 Analytical Instrumentation Questions & Answers
Mathematical Preliminaries
Diagonalization
Nyquist Stability Criterion
Sodium Analyzer Questions & Answers
Time Response of First Order Systems Objective Questions
Realization of Basic Compensators
Control Loop Multiple Choice Questions

Keep Learning

Time Response Analysis

Time Response of Second Order Systems – II

State Variable Analysis and Design

Concepts of State, State Variables & State Model

Analyzers Questions and Answers

Amino-Acid Analyzers Questions & Answers

Pollution Monitoring Instruments Questions and Answers

Nitrogen Oxides Questions & Answers

Chromatography Questions & Answers

Detection System of Gas Chromatography Questions and Answers

Root Locus Concepts Objective Questions

Construction of Root Loci

Digital Control Systems

Z-transform Analysis of Sampled-Data Control Systems

pH Analyzers Questions and Answers

Secondary Reference Electrodes Questions & Answers

Discover More

Gas Valve Sizing

Gas Valve Sizing

Centrifugal Machine Field

Batch Type Centrifugal Automation in Sugar Industries

Mechanical Systems Objective Questions

Mechanical Systems Objective Questions

Design Basis for Fire Detection and Alarm System

Design Basis for Fire Detection and Alarm System

Accuracy of a Manometer

What Affect the Pressure Measurement Accuracy of a Manometer?

Why is IEC 60269 Important

Why is IEC 60269 Important? – Electrical Applications

PLC Commissioning and Testing

PLC Commissioning and Testing Procedure (Programmable Logic Controller)

HART-IP Principle

What is HART- IP ?

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?