Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: MCQ on Flow Measurement
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > MCQ on Flow Measurement

MCQ on Flow Measurement

Last updated: November 27, 2021 5:36 pm
Editorial Staff
Multiple Choice Questions
5 Comments
Share
5 Min Read
SHARE

MCQ ON Flow Measurement

1.A differential pressure transmitter is calibrated 0 to 80 inches of water and transmits a 4 to 20 mA dc signal. This transmitter is placed across an orifice plate which is sized to create 80 inches of water differential 6 gallons per minute. What is the flow rate when the signal is 13 mA dc?

a. 4.5 gpm
b. 3.9 gpm
c. 3.4 gpm
d. 4.9 gpm

Answer: a

2. For the equipment described in the preceding question, what will the signal be if the flow rate is 4 gpm?

a. 13.3 mA dc
b.11.2mAdc
c. 8.9 mA dc
d.6.7mA dc

Answer: b

3. Assume the line used in Questions 1 and 2, is a 1/2-inch schedule 40 pipe (IV = 0.622 inches). find the orifice bore used to satisfy the conditions given if the measured fluid is water at 60 Deg F

a. 0.190 inches
b. 0.556 inches
c. 0.414 inches
d. 0.352 inches

Answer: d

4. The best choice of orifice taps in the preceding problem would be:

a. flange taps
b. vena contracta taps
c. pipe taps
d. corner taps

Answer: d

5. A 2-inch schedule 40 line (lD = 2.067) is used to carry gasoline (SP GR = 0.75). The flow rate is measured with an orifice plate (d = 1.034) and pipe taps are used. At full flow rate, a differential pressure of 50 inches of water is produced. What is the approximate full flow rate in gpm?

a. 30 gpm
b. 53 gpm
c. 250 gpm
d. 36 gpm

Answer: d

6. Assume an 8-inch schedule 160 pipes (ID = 6.813 inches) carries a full flow of 40,000 pounds per hour of dry saturated steam. The static pressure is 335 psi. Flange taps are used and the differential pressure across the orifice plate at the full-flow rate is 100 inches of water. What is the size of the bore in the orifice plate?

a. 4.357 inches
b. 3.645 inches
c. 2.271 inches
d. 5.109 inches

Answer: d

7. Fuel gas is carried in a 6-inch schedule 40 pipe (ID= 6.065 inches). The flow rate is measured with an orifice plate using flange taps and the bare in the orifice is 3.457 inches. The specific gravity is 0.88, the flowing temperature is 60 °F, and the static pressure is 25 psi. Maximum flow rate creates a differential of 20 inches of water. What is the approximate flow rate in cubic feet per day?

a. 1,500,000 SCFD
b. 2,000,000 SCFD
c. 2,500,000 SCFD
d. 3,000,000 SCFD

Answer: a

8. The output of a target flowmeter is:

a. Proportional to volumetric flow rate
b. Proportional to the square of volumetric flow rate
c. Proportional to the square root of volumetric flow rate

Answer: b

9. The output signal or reading of a magnetic flowmeter is:

a. Proportional to volumetric flow rate
b. Proportional to the square of volumetric flow rate
c. Proportional to the square root of volumetric flow rate
d. Inversely proportional to volumetric flow rate

Answer: b

10. With suspended solids and/or entrapped gas in a flowing liquid, the magnetic flowmeter will:

a. Read high
b. Read low
c. Read the liquid flow only
d. Read the correct total volume of the mixture

Answer: a

11. A turbine flowmeter produces an output in the form of pulses. The total number of pulses is:

a. Inversely proportional to flow
b. Directly proportional to total flow
c. Proportional to the square root of flow
d. Proportional to the square of flow

Answer: d

12. Match the head meter primary devices with the application (select a single best answer for each):

a. Orifice Plate         1.High Pressure recovery
b. Flow Nozzle         2. Air ducts
c. Venturi Tube       3. Sediment in liquid
d. Pitot tube            4. Economy & Accuracy are important
e. Elbow taps          5. No straight run available

Answer :  43125

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Objective Questions of Building Fire and Gas Detectors
Top 1000 Analytical Instrumentation Questions & Answers
Infrared Spectrometers Questions & Answers
Analyzers Based on Gas Density Questions & Answers
Process Pressure Measurement Objective Questions
Level and Density Measurement Objective Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
5 Comments
  • Joe says:
    January 4, 2018 at 10:40 pm

    We think question 1 should be c. Can you explain the answer?

    Reply
  • Julius says:
    February 25, 2019 at 10:00 pm

    Most of the answers are wrong

    Reply
  • Shetty says:
    February 26, 2019 at 6:57 am

    Hi Julius, Please share your answers with explanation.

    Reply
  • Maya says:
    March 8, 2019 at 12:08 am

    Can to discuss the answer

    Reply
  • Sneha says:
    April 14, 2022 at 10:45 am

    In question 9 answer should be (a)

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Output Regulator & the Tracking Problem
Difference Equations
Stepper Motors Objective Questions & Answers
Gas Chromatography Questions & Answers
Block diagram Algebra Objective Questions
Z & S Domain Relationship
Carbon Monoxide Questions & Answers
Quadrupole Mass Spectrometer
Experimentation of Transfer Function
Tandem Mass Spectroscopy

Keep Learning

Chromatography Questions & Answers

Chromatographic Behaviour of Solutes Questions & Answers

UV Visible Spectrometers Questions and Answers

UV Visible Spectrometers Questions and Answers

Nonlinear Control Systems

Stability of Nonlinear System – II

Nonlinear Control Systems

Construction of Phase -Trajectories

Digital Circuits Questions & Answers

Logic Families Questions and Answers

Stability in Frequency Domain

Cascade Compensation in Time Domain

Electron Spin Resonance Questions & Answers

Instrumentation of ESR Spectrometer

Liapunov’s Stability Analysis

Liapunov’s Stability Criterion – Part II

Discover More

Level Measurement using DP Transmitters - Open Tank

Open Tank Level Measurement using DP Transmitters Animation

Delta PLC Simulator

How to Work with Delta PLC Simulator?

Hydrogen Sulfide Gas Detector Calibration Procedure

Hydrogen Sulfide Gas Detector Calibration Procedure

Fence grounding specifications

All About Electric Fence Gates

TOC Analyzer Principle

Total Organic Carbon Analyzer Principle

PLC programming for clothes washing machine automation

LS Electric PLC Program Example: Clothes Washing System

Power Electronics Objective Questions

Thyristor Protection Objective Questions and Answers

Seebeck Effect

Seebeck Effect Theory

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?