Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Auger Electron Spectroscopy
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Auger Electron Spectroscopy

Auger Electron Spectroscopy

Last updated: November 27, 2021 5:37 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Auger Electron Spectroscopy

1. The characterisation of auger spectroscopy can be achieved up to which of the following depths?

a) 1 nm
b) 2 nm
c) 4 nm
d) 8 nm

Answer: a

Explanation: The characterisation of auger spectroscopy can be achieved up to a depth of 1nm. Best instruments can characterise few nm.

2. Auger electron spectroscopy can be used for surface chemical analysis in a way similar to which of the following?

a) ESCA
b) SIMS
c) ISS
d) Ion spectroscopy

Answer: a

Explanation: Auger electron spectroscopy can be used for surface chemical analysis in a way similar to ESCA. ESCA is also known as X-ray photoelectron spectroscopy.

3. AES is limited when it comes to very high resolution studies.

a) True
b) False

Answer: a

Explanation: AES is limited when it comes to very high resolution studies. It is very characteristic for various elements.

4. Qualitative chemical analysis is very often performed using which of the following?

a) ESCA
b) SIMS
c) AES
d) Ion spectroscopy

Answer: c

Explanation: Qualitative chemical analysis is very often performed using AES. Auger nomenclature follows the old x-ray notation.

5. Electron ionization can produce which of the following?

a) ESCA electron
b) Auger electron
c) Ion
d) Photon

Answer: b

Explanation: Electron ionization can produce Auger electron. Photo-ionisation can also produce Auger electron.

6. Electron ionisation can produce ESCA electrons.

a) True
b) False

Answer: b

Explanation: Electron ionisation cannot produce ESCA electrons. It can produce only Auger electrons.

7. Which of the following is an Auger transition starting from a hole in 1s levels which would be filled up from the 2p level?

a) KLM transition
b) KLL transition
c) LMN transition
d) LLM transition

Answer: b

Explanation: KLL transition is an Auger transition starting from a hole in 1s levels which would be filled up from the 2p level. 2p electron would also be emitted.

8. In ESCA process, the photon ejects which of the following?

a) 1s electron
b) 1p electron
c) 2s electron
d) 2p electron

Answer: a

Explanation: In ESCA process, the photon ejects 1s electron. For X-ray, an electron drops from the 2p orbit.

9. In Auger process, an electron drops to fill which of the following?

a) 1s hole
b) 1p hole
c) 2s hole
d) 2p hole

Answer: a

Explanation: In Auger process, an electron drops to fill 1s hole. It expels a 2p electron.

10. Auger electron spectroscopy involves the irradiation of the surface to be analysed with a beam of electrons of energy in the _________ range.

a) 1-2 KeV
b) 2-4 KeV
c) 4-8 KeV
d) 1-8 KeV

Answer: a

Explanation: Auger electron spectroscopy involves the irradiation of the surface to be analysed with a beam of electrons of energy in the 1-2 KeV range. Auger and X-ray emission are competitive processes.

11. In Auger spectroscopy, beam currents are typically _____ in a beam of diameter 0.5mm.

a) 5-10 µA
b) 5-20 µA
c) 5-30 µA
d) 5-50 µA

Answer: d

Explanation: In Auger spectroscopy, beam currents are typically 5-50 µA in a beam of diameter 0.5mm. Auger and X-ray emission are competitive processes.

12. Which of the following is the detection limit of Auger Electron Spectroscopy?

a) 0.1% monolayer
b) 0.5% monolayer
c) 1% monolayer
d) 2% monolayer

Answer: b

Explanation: The detection limit of AES is 0.5% monolayer. It has 0.5µ x-y resolution.

13. Which of the following denotes the sample destruction that occurs in Auger electron spectroscopy?

a) None in 95% of sample
b) None in 99% of sample
c) None in 100% of sample
d) Frequent

Answer: d

Explanation: Frequent sample destruction occurs in Auger electron spectroscopy. It is bad for organics.

14. How is the specificity of Auger electron spectroscopy?

a) Very bad
b) Bad
c) Good
d) Very good

Answer: c

Explanation: The specificity of Auger electron spectroscopy is good. ESCA has very good specificity.

15. AES is more sensitive than XPS because of which of the following factors?

a) Binding energies of electrons
b) Kinetic energies of electrons
c) Mass of electrons
d) Mass to charge ratio of electrons

Answer: b

Explanation: AES is more sensitive than XPS because of the difference in kinetic energies of electrons. Ion etching is sometimes necessary for AES.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Hydrocarbons Questions & Answers
Stability Analysis by Describing Functions
MCQ on Flow Measurement
Secondary Reference Electrodes Questions & Answers
Linearizing Effect & Regenerative Feedback MCQ
Solution of State Equations
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Online Analyzers Questions & Answers
Logic Families Questions and Answers
Standard Test Signals Objective Questions
Instrumentation of ESR Spectrometer
Nuclear Magnetic Resonance Spectrometer Questions & Answers
NO2 Analyzer Questions & Answers
Flow Measurement Multiple Choice Questions
Sodium Analyzer Questions & Answers

Keep Learning

Control Systems Multiple Choice Questions

Advances in Control System

Adaptive Control

Time Response Analysis

Robotic Control System – Part I

Mathematical Models of Physical Systems

Differential Equations of Physical Systems & Dynamics of Robotic Mechanisms

Stability in Frequency Domain

The Design Problem

UV Visible Spectrometers Questions and Answers

UV Visible Spectrometers Questions and Answers

Infrared Spectrometers Questions & Answers

Infrared Spectrometers Questions & Answers

Mass Spectrometer Questions and Answers

Time of Flight Mass Spectrometer

Learn More

Electrical Conduit Seal

Assembling an Electrical Conduit Seal

Types of Failures in Control Valves

Types of Failures in Control Valves

Key Facts About RS485 Industrial Network

Key Facts About RS485 Industrial Network

Electrical Machines Questions and Answers

Rotating Machines Electrical Quiz

Feedback Characteristics of Control Systems

Controller Components – Part 2 Objective Questions

Statement List (STL) to Find Highest Value in the Data Block

Statement List (STL) to Find Highest Value

Stroke Checking Procedure for GCV, SRV, IGV, and LFBV

Stroke Checking Procedure for GCV, SRV, IGV, and LFBV

Pressure to Current Converter

Pressure to Current (P/I) Converter Principle

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?