Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Silica Analyzer Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Silica Analyzer Questions & Answers

Silica Analyzer Questions & Answers

Last updated: November 27, 2021 5:36 pm
Editorial Staff
Multiple Choice Questions
2 Comments
Share
7 Min Read
SHARE

Silica Analyzer Questions & Answers

1. Which of the following principles are used in silica analyzer?

a) Amperometric principle
b) Colorimetric principle
c) Coulometric principle
d) Magnetic principle

Answer: b

Explanation: The principle used in silica analyser is colorimetric principle. The colour of the final solution is measured.

2. Which of the following is not added to the sample during analysis during silica analysis?

a) Ammonium Molybdate
b) Sulphuric acid
c) Reducing solution
d) Iodine solution

Answer: d

Explanation: Iodine solution is not added to the sample during analysis. Ammonium molybdate, sulphuric acid and reducing solution are added to the sample.

3. Which of the following detectors are used in silica analyser?

a) Photovoltaic cell
b) Photo multiplier
c) Photo emissive tubes
d) Flame emission detector

Answer: a

Explanation: Photovoltaic cell is used as detector in silica analyser. This detector does not need a battery for operation.

4. The output from both the detectors is given to which of the following devices?

a) Filters
b) Microprocessor
c) Recorder
d) Differential Amplifier

Answer: d

Explanation: The output from both the detectors is given to the differential amplifier. The amplified signal is read through a display.

5. If the differential amplifier gives zero as output then it infers which of the following (Reference output is given to the positive terminal and sample output is given to the negative terminal)?

a) Concentration of silica in sample and reference solution is equal
b) Concentration of silica in reference solution is more than that in the sample solution
c) Concentration of silica in sample solution is more than that in the reference solution
d) Further processing is required to come to any conclusion

Answer: a

Explanation: If the differential amplifier gives zero as output then, it means that the concentration of silica in sample and reference solution is equal. It means that the photodetectors’ output is equal.

6. If the differential amplifier gives a positive output then it infers which of the following (Reference output is given to the positive terminal and sample output is given to the negative terminal)?

a) Concentration of silica in sample and reference solution is equal
b) Concentration of silica in reference solution is more than that in the sample solution
c) Concentration of silica in sample solution is more than that in the reference solution
d) Further processing is required to come to any conclusion

Answer: c

Explanation: If the differential amplifier gives a positive output then, it means that the concentration of silica in sample solution is more than that in the reference solution. It means that the photodetectors’ output is not equal.

7. If the differential amplifier gives a negative output then it infers which of the following (Reference output is given to the positive terminal and sample output is given to the negative terminal)?

a) Concentration of silica in sample and reference solution is equal
b) Concentration of silica in reference solution is more than that in the sample solution
c) Concentration of silica in sample solution is more than that in the reference solution
d) Further processing is required to come to any conclusion

Answer: b

Explanation: If the differential amplifier gives a negative output then, it means that the concentration of silica in reference solution is more than that in the sample solution. It means that the photodetector’s output is not equal.

8. Which of the following statements are true?

a) More light is absorbed if the silica content is high in a solution
b) More light is transmitted if the silica content is high in a solution
c) Less light is absorbed if the silica content is high in a solution
d) More light is absorbed if the silica content is low in a solution

Answer: a

Explanation: More amount of light is absorbed if the silica content is high in a solution. Less amount of light is transmitted if the silica content is high in a solution.

9. How will the photodetector output be if silica content is high in a solution?

a) Output will be high
b) Output will be low
c) Output will be zero
d) Output cannot be determined

Answer: b

Explanation: If silica content is high in a solution, the detector output will be low. This is because more light is absorbed by the solution and less amount of light is transmitted.

10. What will be the final colour of the solution obtained during silica analysis?

a) Pink
b) Red
c) Blue
d) Yellow

Answer: c

Explanation: This method works on the principle of molybdenum blue method. Hence, the colour of the final solution will be blue.

11. During the first sequence of the process, sample is added at the last.

a) True
b) False

Answer: a

Explanation: During the first sequence of the process, sample is added at the last. During the second sequence, all the solutions are added in normal manner.

12. Blank use compensates for the effect of temperature variation.

a) True
b) False

Answer: a

Explanation: Blank use compensates for the effect of temperature variation. It also compensates for various other variables such as ageing of lamps and coloration of the sample.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Recommended Articles

Top 100 Control Systems Objective Questions & Answers
Process Control Questions & Answers
Top 10 Industrial safety Objective Questions
PLC Interview Questions and Answers
Instrumentation of ESR Spectrometer
Feedback Compensation
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
2 Comments
  • Anil patidar says:
    November 5, 2022 at 1:28 pm

    Silica analyser showing value++++++.++

    Reply
    • shoban aftab sindhu says:
      August 30, 2023 at 5:06 pm

      check the regent dosing valve pump and tube someone have chocking compare to others colour of sample is more bluetherefor its showing +++

      Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • William Snyder on Top Non-PLC Certification Courses for Automation Professionals
  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Control Systems Stability and Algebraic Criteria

Routh-Hurwitz Stability Criterion

State Variable Analysis and Design

Pole Placement by State Feedback

Actuators Questions and Answers

Actuators Questions and Answers

Stability in Frequency Domain

Cascade Compensation in Frequency Domain

Spectrometers Questions and Answers

X-Ray Spectroscopy Questions & Answers

Feedback Characteristics of Control Systems

Control of the Effects of Disturbance Signals by Use of Feedback

Pollution Monitoring Instruments Questions and Answers

Carbon Monoxide Questions & Answers

Flow Measurement Questions

MCQ on Flow Measurement

More Articles

Diaphragm Valves

How Diaphragm Valves Work ?

Junction Box Wiring

4-20mA Junction Box versus Fieldbus (FF) Junction Box

Diodes Voltage Quadrupler

Diodes Voltage Quadrupler

Guided-wave Radar Level Measurement Animation

PLC Program for Controlling Sequence of Conveyors with Interlocking

PLC Program for Controlling Sequence of Conveyors with Interlock

Contextual HMI

What is Contextual HMI? – HMI Screens on a Mobile or Tablet

Ultrapure Water in the Semiconductor Industry

Ultrapure Water in the Semiconductor Industry

RTD-standards

How to calculate the tolerance of a RTD sensor

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?