Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Carbon Monoxide Questions & Answers
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Carbon Monoxide Questions & Answers

Carbon Monoxide Questions & Answers

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Carbon Monoxide Questions & Answers

1. Which of the following is the full scale range of Infrared spectroscopy method used for measurement of carbon monoxide?

a) 0-2 ppm
b) 0-500 ppm
c) 0-1 ppm
d) 0-50 ppm

Answer: d

Explanation: The full scale range of Infrared spectroscopy method used for measurement of carbon monoxide is 0-50 ppm. It depends on the characteristic absorption of CO molecule at a particular wavelength.

2. Which of the following is the full scale range of Gas chromatography method used for measurement of carbon monoxide?

a) 0-200 ppm
b) 0-500 ppm
c) 0-1 ppm
d) 0-50 ppm

Answer: a

Explanation: The full scale range of Gas chromatography method used for measurement of carbon monoxide is 0-200 ppm. The detector used in this method is flame ionization detector.

3. Which of the following are not the characteristics of Non-dispersive infrared analyzer method?

a) Easy to maintain
b) High response speed
c) Effect of interfering components is high
d) High sensitivity

Answer: c

Explanation: Effect of interfering components is small for Non-dispersive infrared analyzer method. It depends on the characteristic absorption of CO molecule at a particular wavelength.

4. Non-dispersive infrared analyzer depends on the characteristic absorption of CO molecule at a wavelength of __________

a) 5.4 µm
b) 4.6 µm
c) 8.9 µm
d) 10.8 µm

Answer: b

Explanation: Non-dispersive infrared analyzer depends on the characteristic absorption of CO molecule at a wavelength of 4.6 µm.

5. The zero of the scale is calibrated using which of the following as the sample?

a) Air
b) Water
c) Inert gas
d) Pure nitrogen

Answer: d

Explanation: The zero of the scale is calibrated using pure nitrogen as the sample. Optical filters are used to minimize effects of interfering gases.

6. The disadvantage of Non-dispersive infrared analyzer is that the effect of flow rate is large.

a) True
b) False

Answer: b

Explanation: In Non-dispersive infrared analyzer, the effect of flow rate is small. Optical filters are used to minimize effects of interfering gases.

7. A stripper column used in gas chromatography, can be used to retain which of the following when an air sample is passed through it?

a) CO
b) Methane
c) Light hydrocarbons
d) Heavy hydrocarbons

Answer: d

Explanation: A stripper column can be used to retain heavy hydrocarbons when an air sample is passed through it. It passes CO and methane into the column.

8. Which of the following is not a component of the mixture present in the reference cell of Non-dispersive infrared analyzer?

a) CO
b) Nitrogen
c) Water vapour
d) Hydrogen

Answer: d

Explanation: The reference cell contains a fixed quantity of gases. It contains CO, nitrogen and water vapour.

9. Hydrogen flame ionization detector can be used to detect only the peak of CO and not methane.

a) True
b) False

Answer: b

Explanation: Hydrogen flame ionization detector can be used to detect the peak of both CO and methane. The accuracy is about 2%.

10. CO analyzers based on infrared absorption would give greater sensitivity under which of the following conditions?

a) With larger cell path lengths
b) With smaller cell path lengths
c) By changing the gases in the reference cell
d) By increasing the sample flow rate

Answer: a

Explanation: CO analyzers based on infrared absorption would give greater sensitivity with larger cell path lengths. If 1m path length is given, the range is from 0 to 50ppm.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

AC Circuits Multiple Choice Questions
Stability Analysis
Thermal Conductivity Analyzers Questions & Answers
Feedforward Control Questions and Answers
Basic ESR Spectrometer
Infrared Gas Analyzers Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Ion Analyzer Questions & Answers
Concepts of State, State Variables & State Model
Stepper Motors Objective Questions & Answers
Diagonalization
Gamma Camera Questions & Answers
Ammonia and Fluoride Electrode Questions & Answers
Pneumatic Control Mechanisms Objective Questions
Z-transform Analysis of Sampled-Data Control Systems

Keep Learning

Advances in Control System

Adaptive Control

Stability in Frequency Domain

Cascade Compensation in Time Domain

Mass Spectrometer Questions and Answers

Time of Flight Mass Spectrometer

Mass Spectrometer Questions and Answers

Mass Spectrometer Questions & Answers

Mathematical Models of Physical Systems

Block diagram Algebra Objective Questions

Sensors and Transducers Objective Questions

Top 1000 Instrumentation Engineering Objective Questions

Mass Spectrometer Questions and Answers

Liquid Chromatograph- Mass Spectrometer

Time Response Analysis

Robotic Control System – Part II

Learn More

Gate Valve

How Gate Valves Work ?

Control systems in industrial projects

Interactions With Process Control Systems Philosophy

Power Supply Sizing for Industrial Automation Systems

Power Supply Sizing for Industrial Automation Systems

PLC Program for Blinking Lamp on 5 Seconds Interval

PLC Program for Blinking Lamp on 5 Seconds Interval

Hydraulic Motor Forward and Reverse Control with Simulation

Hydraulic Motor Forward and Reverse Control with Simulation

Thyristor Interview Questions & Answers

Thyristor Interview Questions & Answers

Bubbler level measurement

what is a Bubbler System?

Coriolis mass flowmeter Density Measurement

How Coriolis Mass Flow Meter Measure Density?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?