Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Operation of Chromatography Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Operation of Chromatography Questions & Answers

Operation of Chromatography Questions & Answers

Last updated: November 27, 2021 5:37 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Operation of Chromatography Questions & Answers

1. Which of the following steps takes place after injection of feed in Column chromatography?

a) Detection of components
b) Separation in column
c) Elution from the column
d) Collection of eluted component

Answer: b

Explanation: The operation that occurs after the injection of feed is a separation in the column. After that, elution from the column and detection of components takes place.

2. Components with the strong attraction to the support move more slowly than components with weak attraction.

a) True
b) False

Answer: a

Explanation: Different components will adsorb to the stationary phase in varying degrees. Components with the strong attraction to the support move more slowly than components with weak attraction.

3. What happens during the ‘elution from the column’ phase chromatography?

a) Components with the greatest affinity elute first
b) Components with least affinity elute first
c) Components elute in a random manner
d) Components elute according to their concentration in the mixture

Answer: b

Explanation: During the elution phase, different components elute at different times. Components with least affinity elute first.

4. In chromatogram, the position of peaks on the time axis can be used to determine which of the following?

a) Components of sample
b) Amount of component in sample
c) Column efficiency
d) Column resolution

Answer: a

Explanation: Chromatogram is a detector that responds to concentration solute and is placed at the end of the column. The position of peaks on the time axis can be used to determine components of the sample.

5. In chromatogram, the area under the peak can be used to determine which of the following?

a) Components of sample
b) Amount of component in sample
c) Column efficiency
d) Column resolution

Answer: b

Explanation: Chromatogram is a detector that responds to concentration solute and is placed at the end of the column. The area under the peak can be used to determine an amount of component in the sample.

6. The stationary phase could be a viscous liquid coated over a surface of solid particles.

a) True
b) False

Answer: a
Explanation: The stationary phase could be a viscous liquid coated over a surface of solid particles. The solid particles can also be the stationary phase.

7. Given below is a diagram of separation of two components of a mixture in a chromatographic column. From the diagram, infer which component has a lesser affinity to the stationary phase.

a) W
b) X
c) Y
d) Z

Answer: c

Explanation: Y will elute from the column first. Components with least affinity to the stationary phase will elute first.

8. Using Chromatogram as detector in Chromatography, a graph is obtained between ____________ and time.

a) Quantity
b) Density
c) Concentration
d) Specific gravity

Answer: c

Explanation: Using Chromatogram as a detector in Chromatography, a graph is obtained between concentration and time. The detector is placed at the bottom of the column.

9. In older analytical methods, which of the following methods were used to allow movement of mobile phase?

a) Pumps
b) Pressure
c) Gravity
d) Blowing air into the column

Answer: c

Explanation: In older analytical methods, gravity facilitated the movement of the mobile phase. The effect of capillary action was also employed to allow movement.

10. Given below is the diagram of ‘Process of chromatographic column’. Identify the unmarked component in the process.

a) Reservoir
b) Collection tank
c) Microprocessor
d) Detector

Answer: d

Explanation: The unmarked component is the detector. It is placed at the bottom of the column. It responds to solute concentration.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Online Analyzers Questions & Answers
State Variable Analysis – Part II
Measurement and Instrumentation Objective Questions – Part 4
Parameter Optimization : Servomechanims
Tuning of PID Controllers
Liquid Chromatography Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Amino-Acid Analyzers Questions & Answers
DC Circuits Multiple Choice Questions
Flow Measurement Multiple Choice Questions
Quadrupole Mass Spectrometer
Closed-Loop Frequency Response
Direct Method & Constructing of Liapunov for the Linear & Non-Linear System
X-Ray Diffractometers Questions & Answers
Permit to Work System Online Test
Spectrum Analysis of Sampling Process
Components of Mass Spectrometer Questions & Answers

Keep Learning

Stability in Frequency Domain

Feedback Compensation

Feedback Control Questions & Answers

Feedback Control Loop Questions & Answers

Process Control Questions & Answers

Process Control Questions & Answers

Spectrometers Questions and Answers

Total Reflection Spectrometer Questions & Answers

Control Systems Stability and Algebraic Criteria

Routh-Hurwitz Stability Criterion

Optimal Control Systems

Optimal Control Problems – Part 1

Mathematical Models of Physical Systems

Signal Flow Graphs Objective Questions

Digital Circuits Questions & Answers

Logic Families Questions and Answers

Discover More

Dead Weight tester

Dead Weight Tester Working Animation

Filtering and Dynamic Compensation Objective Questions

Filtering and Dynamic Compensation Objective Questions

Fail-Close Valve

What is a Fail-Close Valve? – Advantages and Disadvantages

Condensate Automation in the Sugar Industry

Condensate Automation in the Sugar Industry

Career Opportunities in Instrumentation Engineering

Job and Career Opportunities in Instrumentation Engineering

Dissolved Oxygen Analyzers Interview Questions

Dissolved Oxygen Analyzer Interview Questions & Answers

Siemens PLC Course for Beginners

Siemens PLC Course for Beginners: Problems and Solutions

3-Wire, Three-Phase Delta Wiring System

3-Wire, Three-Phase Delta Wiring System

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?