Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Why rating of Synchronous Generators and Alternators in MVA or KVA
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Machines > Why rating of Synchronous Generators and Alternators in MVA or KVA

Why rating of Synchronous Generators and Alternators in MVA or KVA

Last updated: April 25, 2016 2:58 pm
Editorial Staff
Electrical Machines
No Comments
Share
2 Min Read
SHARE

Normally the rating of synchronous generators or alternators will be in KVA or MVA instead of kW rating.

Electrical apparatus or machines are usually rated the load which it can carry without overheating and damaging to insulation. i.e, rating of the electrical machines are governed by the temperature rise caused by the internal loss of the machine. The copper loss in the armature depends on the strength of the armature current and core loss depends on voltage and these losses are independent of the power factor.

The reason for which the transformers and synchronous generators are rated in volt-amperes instead of watts is that manufacturer does not know at what power factor does these equipments are going to operate. On the other hand while manufacturing the motors manufacturer specifies the power factor at which the motor should be operate. This is the reason why the motor loads (including synchronous motors are rated in kw) are rated in wattage power.

In the case of alternator and transformers manufacturer does not know the operating power factor. Hence they are rated in KVA or MVA

Consider a generator whose output power is 1000kVA, for different power factors 0.2, 0.5 and 0.8 and unity respectively the output power in kW will be 200, 500, 800 and 1000kW.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Advantages & Disadvantages of Synchronous Motors
DC Motor Speed Control
Synchronous Generator Salient Pole vs Non Salient Pole
Different Types of Transformers
Difference between Star and Delta Connections
Why Armature is placed on Stator for Synchronous machines
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

AC Motor Speed Control
Faults in a Transformer
What happen When Synchronous Generator loss Excitation
What is Auto Reclosing?
Differences Between AC and DC Motors
6.6kV HV Induction motor Protection
Star to Delta and Delta to Star Conversion Formula
Difference between Induction motor and Synchronous motor

Keep Learning

Types of Transfomer Cooling Methods

AC Induction Motor Construction

Basics of AC Induction Motors

Advantages & Disadvantages Induction Motor

Applications of Synchronous Motors

VFD circuit

AC Motor Braking

What is a transformer tap changer?

Induction Motors Faults and Protection

Electrical Machines Objective Questions

Electrical Machines Objective Questions

Learn More

Difference between LVDT and RVDT

Difference between LVDT and RVDT?

Magnetic Level Indicator

Magnetic Level Indicator Principle, Limitations, Installation and Calibration

Comparison of Level Meters - Level Measurement Instruments

Comparison of Level Meters – Level Measurement Instruments

Synchronous Motor Principle

Synchronous Motors

Voltage Drop in a Series Circuit

Series Resistance

AC to DC Conversion with a Commutator

DC Machines Terminology

DTMF Based Project Topics and Ideas

Top 100 DTMF Based Projects, Topics and Ideas

Two out of Three Logic Analogy

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?