Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Feedback Control Loop Questions & Answers
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Instrumentation MCQ > Feedback Control Loop Questions & Answers

Feedback Control Loop Questions & Answers

Last updated: June 21, 2025 10:05 am
Editorial Staff
Instrumentation MCQ Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Feedback Control Loop Questions & Answers

1. With adequate gain and inphase feedback any system will:

a. Drift
b. Oscillate
c. Increase amplitude
d. Degenerate

Answer: b

2. The natural frequency at which a closed-loop system will cycle depends upon:

a. The amplifier gain
b. The attenuation provided by the process
c. The phase shift provided by the resistance-capacitance and dead time networks that exist in the system
d. Resonance

Answer: c

3. The Bode diagram describes:

a. Gain and phase shift through the usable frequency range
b. The system’s linearity
c. The reaction to a step change
d. The recovery curve that will result from a load change

Answer: a

4. All systems may be assumed to be:

a. Linear
b. Nonlinear
c. Linear for the purpose of initial consideration but with full knowledge that this may not be the case
d. Nonlinear for purposes of analysis with the exception that the system may prove to be linear

Answer: c

5. A closed-loop control system that employs a three-mode controller:

a. Can oscillate or cycle at only one frequency
b. Can oscillate or cycle at several frequencies. depending on controller adjustment
c. Will not oscillate because of the stability provided by derivative
d. Will produce only damped oscillations with a 0.25 damping ratio

Answer: b

6. We have a closed-loop control system which is cycling. We should:

a. Increase the proportional band
b. Increase integral action
c. Check and adjust both
d. Immediately shut it down

Answer: c

7. A proportional controller is being used to control a process and the offset between set point and control point must be held to a minimum. This would dictate that the proportional band

a. Be as narrow as possible
b. Be as wide as possible
c. Be of moderate value
d. Does not relate to the problem

Answer: a

8. The system gain of the closed-loop control system:

a. Refers to the process gain
b. Refers to the gain of the measurement and control devices
c. Refers to the total gain of all components. including measurement, controller, valve operator, valve, and process
d. Relates only to the gain of the controller

Answer: b

9. If a closed-loop control system employs a straight proportional controller and is under good control. offset:

a. Will vary in magnitude
b. Will not exceed one-half of the proportional bandwidth
c. Will exceed the deviation
d. Is repeated with each reset

Answer: b

10. Any closed-loop system with in-phase feedback and a gain of one or more will:

a. Degenerate
b. Cycle or oscillate
c. Exhibit a 0.25 damping ratio
d. Produce square waves

Answer: b

11. If a closed-loop control system is adjusted to produce a 0.25 damping ratio when subjected to a step change, the system gain is:

a. 0.1
b. 0.25
c. 0.5
d. 1.0

Answer: c

12. A straight proportional controller is employed to control a process of Narrowing the proportional band will:

a. Not change the offset
b. Decrease the offset
c. Always cause cycling
d. Never cause cycling

Answer: b

13. The type of process that most often can benefit from derivative is:

a. Flow
b. Level
c. Temperature
d. Pressure

Answer: c

14. Pure dead time in a process contributes a gain or:

a. Zero
b. Infinite
c. Depends upon dynamics
d. One

Answer: d

15. Referring to Figure, the transmitter span is 200 °F; the controller proportional band is adjusted to 150 percent; the equal percentage valve delivers saturated steam containing 40,000 Btu per minute at full open; and water enters the exchanger at 50°F and is heated to 200 DegF at a 40 gpm maximum flow rate. The static gain of this control loop is approximately:

Instrumentation MCQ

Fig : Responsec haracteristicso Ce ache lementi n a Ceedbaccko ntrolloop-heat, exchangepr rocesso

a. 0.5
b. 1.0
c. 1.5
d. 2.0

Answer: a

16. The integral control mode is:

a. Phase-Ieading
b. Phase-Iagging
c. Inphase
d. Phase-reversing

Answer: b

17. The derivative control mode is

a. Phase-Ieading
b. Phase-Iagging
c. Inphase
d. Phase-reversing

Answer: a

18. The most common combination of control modes found in the typical process plant is:

a. Proportional-only
b. Proportional, integral, and derivative
c. Proportional-plus-integral
d. On/off

Answer: c

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Displacement Transducers Objective Questions
Oscillators and Signal Generators Objective Questions
Multiplexers and Demultiplexers Objective Questions
Level and Density Measurement Objective Questions
Construction of Phase -Trajectories
Solution of State Equations
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Ammonia and Fluoride Electrode Questions & Answers
Hydrocarbons Questions & Answers
Relative Stability Analysis
Measurement and Instrumentation Objective Questions – Part 5
Vibration Probes Questions and Answers
Mathematical Preliminaries
Gas Solid Chromatography Questions & Answers
Control Loops Objective Questions and Answers

Keep Learning

Ion Spectrometers Questions & Answers

Instrumentation of Ion Spectroscopy

Frequency Response MCQ

All-pass & Minimum-phase Systems

Measurement of Phase Angle Objective Questions

Measurement of Phase Angle Objective Questions

Types of Flow Meters MCQ - Instrumentation and Control

Types of Flow Meters MCQ – Instrumentation and Control

Ion Spectrometers Questions & Answers

Ion Spectroscopy Questions & Answers

Electronic Amplifiers Objective Questions

Electronic Amplifiers Objective Questions

Control Valves Multiple Choice Questions

Control Valves Multiple Choice Questions

Fiber Optics Objective Questions and Answers

Fiber Optics Objective Questions and Answers

Learn More

Parallel Circuit Unknown Resistance

Simplified Formulas for Parallel Circuit Resistance Calculations

Hybrid Solar Power System

Difference Between Normal Inverter and Solar Inverter

Feedback Pneumatic Load cell Objective Questions

Feedback Pneumatic Load cell Objective Questions

Communicate between the PLC program and HMI program

Design a Program Using Studio 5000 and FactoryTalk View Studio

Control systems in industrial projects

Interactions With Process Control Systems Philosophy

Color detection PLC logic

Conveyor Sorting System with Color Detection PLC Logic

On Off Valve Root Cause Analysis

Root Cause Analysis for FRP Line Damaged due to On-Off Valve

Stability in Frequency Domain

Closed-Loop Frequency Response

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?