Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Instrumentation of ESR Spectrometer
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Instrumentation of ESR Spectrometer

Instrumentation of ESR Spectrometer

Last updated: November 27, 2021 5:37 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
6 Min Read
SHARE

Instrumentation of ESR Spectrometer

1. Which of the following is used as detector crystal in ESR spectrometer?

a) Silicon rectifier
b) Silicon tungsten rectifier
c) Silicon boron rectifier
d) Silicon quartz rectifier

Answer: b

Explanation: Silicon tungsten rectifier is used as detector crystal in ESR spectrometer. This is the commonly used detector.

2. After detection, the resulting signal will have which of the following frequencies?

a) 1 kHz
b) 10 kHz
c) 100 kHz
d) 1000 kHz

Answer: c

Explanation: After detection, the resulting signal will have 100 kHz. It contains ESR information.

3. Which of the following is the modulation amplitude range of ESR spectrometer?

a) 1mG to 10G
b) 2mG to 15G
c) 3mG to 20G
d) 5mG to 40G

Answer: d

Explanation: 5mG to 40G is the modulation amplitude range of ESR spectrometer. It is applied in steps.

4. In which of the following ranges will the receiver time constant of the ESR spectrometer lie?

a) 0 to 10 s
b) 0.3 to 1 s
c) 0.03 to 10 s
d) 0.003 to 100 s

Answer: d

Explanation: The receiver time constant of the ESR spectrometer lies from 0.003 to 100 s. It is one of the important parameters of ESR spectrometer.

5. Which of the following is the oscilloscope field width of the ESR spectrometer?

a) 0.2 to 40 G
b) 0.1 to 20 G
c) 0 to 10 G
d) 0.01 to 20 G

Answer: a

Explanation: The oscilloscope field width of the ESR spectrometer lies between 0.2 to 40 G. it is one of the important parameters.

6. The magnet used in ESR spectrometer provides a magnetic field which can be varied from ________ to _______

a) 20 mgauss, 100mgauss
b) 200 mgauss, 20kgauss
c) 20 mgauss, 20kgauss
d) 100 mgauss, 10kgauss

Answer: b

Explanation: The magnet used in ESR spectrometer provides a magnetic field which can be varied from 200 mgauss to 20kgauss. It is calibrated in steps.

7. Which of the following sensor is used in ESR spectrometer?

a) Hall-effect sensor
b) Load cell
c) Strain gauge
d) Bourdon gauge

Answer: a

Explanation: Hall-effect sensor is used in ESR spectrometer. It is given as an input to the summation circuit.

8. Which of the following oscillator is used as 1230 Hz oscillator?

a) Hartley oscillator
b) Crystal oscillator
c) RC oscillator
d) Wien bridge oscillator

Answer: d

Explanation: Wien bridge oscillator is used as 1230 Hz oscillator. The output level is internally regulated.

9. What does AFC stand for?

a) Auto frequency correct
b) Automated frequency correct
c) Automatic frequency control
d) Automatic frequency circuit

Answer: c

Explanation: AFC stands for automatic frequency control. A 70 kHz AFC is used.

10. Klystron requires _______ for the klystron beam and up to _____ for the klystron reflector.

a) +400 V, -730 V
b) +650 V, -400 V
c) +200 V,-530 V
d) +180 V,-270 V

Answer: b

Explanation: Klystron requires +650 V for the klystron beam and up to -400 V for the klystron reflector. Klystron is also known as reflex oscillator.

11. The klystron body is insulated from ground by an insulating gas casket.

a) True
b) False

Answer: a

Explanation: The klystron body is insulated from ground by an insulating gas casket. It is placed between klystron flange and water cooling flange.

12. The 100 kHz oscillator acts as which of the following?

a) Transmitter
b) Receiver
c) Modulator
d) Transmitter and receiver

Answer: d

Explanation: The 100 kHz oscillator acts as the transmitter and receiver. It is crystal controlled.

13. Which of the following removes residual harmonics from the phase-detected signal?

a) High-pass filter
b) Low-pass filter
c) Band-pass filter
d) Chopper

Answer: b

Explanation: Low-pass filter removes residual harmonics from the phase-detected signal. It removes the residual 100 kHz if any.

14. The oscilloscope is used to display the klystron mode.

a) True
b) False

Answer: a

Explanation: The oscilloscope is used to display the klystron mode. It provides visual observation of rapidly changing signals.

15. In the sample cell, which of the following is selected to give maximum optical transmission in the UV-visible region?

a) Tungsten
b) Quartz
c) Phosphor
d) Potassium

Answer: b

Explanation: In the sample cell, quartz is selected to give maximum optical transmission in the UV-visible region. Aqueous sample cells are specially designed.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Cascade Compensation in Time Domain
Silica Analyzer Questions & Answers
Chromatographic Behaviour of Solutes Questions & Answers
Digital Circuits Questions & Answers
Measurement and Instrumentation Objective Questions – Part 5
Feedback Compensation
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Special Designs of Ion Selective Electrodes Questions & Answers
Root Locus Concepts Objective Questions
Carbon Monoxide Questions & Answers
Digital Control Systems Multiple Choice Questions
Instrumentation of Ion Spectroscopy
Permit to Work System Online Test
Stability of Nonlinear System
Constructing Phase-Trajectories
Frequency Response MCQ
Ion Spectroscopy Questions & Answers

Keep Learning

Ion Analyzers Questions and Answers

Ion Analyzer Questions & Answers

Ion Spectrometers Questions & Answers

Instrumentation for Electron Spectroscopy

Analyzers Questions and Answers

Dissolved Oxygen Analyzer Questions and Answers

Mass Spectrometer Questions and Answers

Magnetic Deflection Mass Spectrometer Questions & Answers

Control Systems Stability and Algebraic Criteria

Concept of Stability in Control Systems

Feedback Characteristics of Control Systems

Feedback and Non-feedback Systems Objective Questions

Control Systems Multiple Choice Questions

Digital Circuits Questions & Answers

Logic Families Questions and Answers

Discover More

Types of Capacitors

Types of Capacitors

NAMUR OPEN ARCHITECTURE

What is NAMUR OPEN ARCHITECTURE?

HVAC System Heat Transfer Loops

Heat Transfer Loops in HVAC System

Transmission Control Protocol

Difference Between TCP and UDP

CAN Protocol with the OSI Model

Basics for CAN Bus Protocol – Controller Area Network

Hydraulic Actuators

Working Principle of Hydraulic Actuators

PLC Programming Limit Switch

PLC Programming Example using Limit Switch

AI AO DI DO Signals

What are AI, AO, DI, and DO? – Definition, Examples, Purpose

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?