Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Ion Selective Electrodes Questions and Answers
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Ion Selective Electrodes Questions and Answers

Ion Selective Electrodes Questions and Answers

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
6 Min Read
SHARE

Ion Selective Electrodes Questions and Answers

1. Which of the following is not the characteristic of ion selective electrodes?

a) It is fragile
b) Easy to use
c) Available in different sizes and shapes
d) It is insensitive to many ions

Answer: a

Explanation: Ion selective electrode is rugged in construction. It is highly selective to a particular ion.

2. In glass membrane electrode, the glass containing 11% Na2O, 18% Al2O3, 71% SiO2 is highly sensitive to which of the following ions?

a) Sodium
b) Hydrogen
c) Nitrogen
d) Chlorine

Answer: a

Explanation: In glass membrane electrode, the glass containing 11% Na2O, 18% Al2O3, 71% SiO2 is highly sensitive to sodium ions. Glass electrodes can be used to measure various ions by changing the glass membrane composition.

3. In liquid membrane electrode, the liquid ion exchanger is held in a porous disc of _____________

a) Solid material
b) Semi-permeable membrane
c) Hydrophobic material
d) Water absorbing material

Answer: c

Explanation: In liquid membrane electrode, the liquid ion exchanger is held in a porous disc of hydrophobic material. It is a water repelling material.

4. In recent liquid membrane electrodes, the porous liquid membrane is replaced with which of the following?

a) Polyvinyl chloride
b) Polyacryl chloride
c) Polyester membrane
d) Polyacryl amide

Answer: a

Explanation: In recent liquid membrane electrodes, the porous liquid membrane is replaced with polyvinyl chloride membrane. The measured potential is a direct measure of concentration of specific ion.

5. Which of the following is used in potassium electrode in liquid membrane electrodes?

a) Ionomycin
b) Valinomycin
c) Nonactin
d) Gramicidin

Answer: b

Explanation: Valinomycin is used in potassium electrode in liquid membrane electrodes. It is a doughnut shaped electron rich pocket.

6. In solid state membranes, the body of the electrodes are made of which of the following?

a) Polyvinyl chloride
b) Plastic
c) Polythene
d) Teflon

Answer: d

Explanation: In solid state membranes, the body of the electrodes are made of Teflon. The membrane is held in position using epoxy resin.

7. Which of the following is not the characteristic of ion selective electrodes?

a) Simple to use
b) Inexpensive
c) Narrow concentration range
d) Operates in wide range of temperature

Answer: c

Explanation: Ion selective electrodes have wide concentration range. It is highly selective to a particular ion.

8. Ion selective electrode are unaffected by colour or turbidity of the solution.

a) True
b) False

Answer: a

Explanation: Ion selective electrode are unaffected by colour or turbidity of the solution. It operates in wide range of temperature.

9. Which of the following is not a problem of ion selective electrodes?

a) Interference with other ions
b) Output is influences by ionic strength
c) Drift in electrode potential during a sequence of measurements
d) Can measure only positive ions

Answer: d

Explanation: Ion selective electrodes can measure both positive and negative ions. It is affected by interference from other ions.

10. Which of the following is the effective concentration measured at the electrode head?

a) Selectivity co-efficient
b) Ionic strength
c) Activity
d) Activity co-efficient

Answer: c

Explanation: Activity is the effective concentration measured at the electrode head. Concentration is different from activity.

11. The value of activity co-efficient is always in which of the following ranges?

a) Zero
b) Less than zero
c) Less than 1
d) Greater than 1

Answer: c

Explanation: The value of activity co-efficient is always less than 1. It is the ratio of activity divided by concentration.

12. Which of the following specifies the relation between ionic strength and activity co-efficient?

a) Directly proportional
b) Inversely proportional
c) Equal
d) No particular relation

Answer: b

Explanation: Activity co-efficient and ionic strength are inversely proportional to each other. If the ionic strength increases, the value of activity decreases.

13. The difference between measured activity and actual concentration becomes higher at higher concentration. Is this statement true or false?

a) True
b) False

Answer: a

Explanation: The difference between measured activity and actual concentration becomes higher at higher concentration. Similarly, it decreases at lower concentrations.

14. Given below is the diagram of liquid membrane electrode. Identify the unmarked component.

a) Solid material
b) Semi-permeable membrane
c) Hydrophobic material
d) Water absorbing material

Answer: c

Explanation: The unmarked component is porous hydrophobic material. It holds the liquid ion exchanger.

15. Ion selective electrodes have ________ linear range and _________ detection limit than the pH electrode.

a) Lower, lower
b) Lower, higher
c) Higher, lower
d) Higher, higher

Answer: b

Explanation: Ion selective electrodes have lower linear range and higher detection limit than the pH electrode. It works on effectively narrow pH.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

State Variables & Linear Discrete Time Systems
Controllability & Observability
Polar Plots MCQ
PID Controller Multiple Choice Questions
Control Valves Multiple Choice Questions
Construction of Root Loci
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Effect of Adding a Zero to a System – II
Controller Components – Part 2 Objective Questions
Objective Questions of Building Fire and Gas Detectors
Nyquist Stability Criterion
pH Measurement Questions & Answers
Amino-Acid Analyzers Questions & Answers
Design Considerations for Higher Order Systems
Diagonalization

Keep Learning

Radiochemical Questions and Answers

Gamma Camera Questions & Answers

Ion Analyzers Questions and Answers

Special Designs of Ion Selective Electrodes Questions & Answers

Digital Control Systems

Compensation Techniques : Control Systems

Mass Spectrometer Questions and Answers

Inductively Coupled Plasma Mass Spectrometer

Permit to Work System Online Test

Permit to Work System Online Test

Radiochemical Questions and Answers

Fundamentals of Radiochemical Methods Questions

State Variable Analysis and Design

Observer Systems

Stability in Frequency Domain

The Design Problem

Learn More

PLC Program for Automatic Bottle Rejection System

PLC Program for Automatic Bottle Rejection System

Example Ladder Logic Diagram

What is Relay Logic ?

Ziegler-Nichols Closed Loop Tuning Procedure

Ziegler-Nichols Closed Loop Tuning Procedure

Transmitter Performance and Calibration Frequency

How to Calculate Transmitter Performance and Calibration Frequency?

Eddy current Vibration Sensor Principle

Non-contact Vibration Measurement

Industrial Instruments Questions and Answers

Industrial Instruments Questions and Answers

triac

Turning Off SCR – Commutation

DP type Flow Transmitter Calibration

DP type Flow Transmitter Preventive Maintenance and Calibration

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?