Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Shunt Capacitor Advantages in Power System
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Power Systems > Shunt Capacitor Advantages in Power System

Shunt Capacitor Advantages in Power System

Last updated: September 20, 2016 2:22 pm
Editorial Staff
Power Systems
No Comments
Share
2 Min Read
SHARE

Normal loads on ac supply system are inductive in nature (eg: motors, power transformers, voltage regulators, induction furnace, choke coils, magnetic systems, discharge tubes etc) Inductive power requires reactive power in addition to active power (active power is required to do the true work). The reactive power increases the load imposed on the system.

When a capacitor is installed across an inductive load (i.e, parallel to the load), the load starts receiving reactive power from the capacitor and thus capacitor power neutralizes the reactive power requirement of the inductive load. Consequently the supply system is relieved from producing reactive power to the load and it can able to deliver greater active power. When the power factorimproves towards unity, the transmission losses decreases due to reduced current and the system voltage improves. A healthy supply enables machines and protection equipment to give optimum output in terms of performance and operational life span.

Some of the advantages due to installing shunt capacitors in the power system are explained below

  • For a particular active power (kW) the resultant demand (kVA) is subsequently reduced. So additional machines can be installed for given sanction of kVA load
  • Since voltage drop is minimized, motor torque capability ( Torque α Voltage2 ) improves, so starting time and the motor heating gets considerably reduced. Motor current requirement for the same output is lesser
  • Because of  less heating, the ageing of the insulation becomes slow and thus the life of the machine and the cables increases
  • Switchgear wear and tear is minimized because of lesser arcing energy dissipation (i.e, lesser acing time) at higher power factor
  • Reduced losses in the feeders lead to lesser voltage drop, hence greater voltage regulation
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Harmonics effect on Induction Motor
Advantages and Disadvantages of Per Unit System
Rotor Angle Stability of Synchronous Generators in Power System
Auto Recloser Circuit Breaker in Power System
Neutral Grounding Practice in Power System
Underground Cable Fault Identification Methods
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Ungrounded or Isolated Neutral System Disadvantages
Factors affect Voltage Level Selection in Service System
Why Reactive Power is Generated at Load
Reactive Power Sources and Sinks in Power System
Power System Protection Multiple Choice Questions
Generating Station Grounding Principles
Current Limiting Reactors and Short Circuit Currents
Electrical Power System Protection Quiz

Keep Learning

Shunt Vs Series Capacitors Advantages

Shunt Vs Series Capacitors Advantages

Silicon Carbide Lightning Arresters Working Principle

harmonics-disadvantages-in-power-system

Harmonics Disadvantages in Power System

why-symmetrical-components-used

Why Symmetrical Components Used for Unbalanced faults in Power System

Corona-Ring-on-Surge-Arresters

Corona Ring on Surge Arresters and other EHV equipment

Voltage Variations Effects on Power Plant Equipment

Voltage Variations Effects on Power Plant Equipment

Advantages & Disadvantages of AC power and DC power

Advantages & Disadvantages of AC power and DC power

harmonics-effect-on-transformer

Harmonics effect on Transformer

Learn More

Instrumentation Engineer Interview Questions

Interview Questions on PID Controllers

Synchronous Motor Working Principle

How PLC controls a ON-OFF Valve

PLC Valve Control Ladder Logic Programming

Basic Power Electronics Interview Questions

Basic Power Electronics Interview Questions

How Does Starlink Work

How Does Starlink Work?

Electrical Machines Questions and Answers

Transformer Open Circuit and Short Circuit Test

Top 100 Zigbee Projects for Engineering Students

Top 100 Zigbee Projects for Engineering Students

Power Plant Blackout

What Happens When the Power Plant Blackout?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?