Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Shunt Capacitor Advantages in Power System
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Power Systems > Shunt Capacitor Advantages in Power System

Shunt Capacitor Advantages in Power System

Last updated: September 20, 2016 2:22 pm
Editorial Staff
Power Systems
No Comments
Share
2 Min Read
SHARE

Normal loads on ac supply system are inductive in nature (eg: motors, power transformers, voltage regulators, induction furnace, choke coils, magnetic systems, discharge tubes etc) Inductive power requires reactive power in addition to active power (active power is required to do the true work). The reactive power increases the load imposed on the system.

When a capacitor is installed across an inductive load (i.e, parallel to the load), the load starts receiving reactive power from the capacitor and thus capacitor power neutralizes the reactive power requirement of the inductive load. Consequently the supply system is relieved from producing reactive power to the load and it can able to deliver greater active power. When the power factorimproves towards unity, the transmission losses decreases due to reduced current and the system voltage improves. A healthy supply enables machines and protection equipment to give optimum output in terms of performance and operational life span.

Some of the advantages due to installing shunt capacitors in the power system are explained below

  • For a particular active power (kW) the resultant demand (kVA) is subsequently reduced. So additional machines can be installed for given sanction of kVA load
  • Since voltage drop is minimized, motor torque capability ( Torque α Voltage2 ) improves, so starting time and the motor heating gets considerably reduced. Motor current requirement for the same output is lesser
  • Because of  less heating, the ageing of the insulation becomes slow and thus the life of the machine and the cables increases
  • Switchgear wear and tear is minimized because of lesser arcing energy dissipation (i.e, lesser acing time) at higher power factor
  • Reduced losses in the feeders lead to lesser voltage drop, hence greater voltage regulation
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Voltage Variations Effects on Power Plant Equipment
Rotor Angle Stability of Synchronous Generators in Power System
Reactive Power Sources and Sinks in Power System
Why Reactive Power is Generated at Load
Power System Protection Multiple Choice Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals
  • Vaishnavi on Free Instrumentation Course for Trainee Engineers

Related Articles

harmonics-disadvantages-in-power-system

Harmonics Disadvantages in Power System

harmonics-effect-on-induction-motor

Harmonics effect on Induction Motor

Auto Recloser Circuit Breaker in Power System

Auto Recloser Circuit Breaker in Power System

Power System Protection Quiz

Electrical Power System Protection Quiz

Why Grounding

Generating Station Grounding Principles

current-limiting-reactors-and-short-circuit-currents

Current Limiting Reactors and Short Circuit Currents

Advantages & Disadvantages of AC power and DC power

Advantages & Disadvantages of AC power and DC power

Shunt Vs Series Capacitors Advantages

Shunt Vs Series Capacitors Advantages

More Articles

Instrument Air Sizing

Instrument Air Sizing

Python in Industrial Automation

Python in Industrial Automation and Control Systems

Electrical Heating Objective Questions and Answers

Electrical Heating Objective Questions and Answers

Magnetostrictive Level Transmitter Calibration

Magnetostrictive Level Transmitter Calibration Procedure

Direct Acting Solenoid Valve

Top 5 Things for selecting a Solenoid Valve

Level Measurement using DP Transmitters - Open Tank

Open Tank Level Measurement using DP Transmitters Animation

Instrument Air Quality

Instrument Air Quality

Gamp 5 Compliance in Pharmaceutical Industry

What is Gamp 5 Compliance in Pharmaceutical Industry?

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?