Skip to content
  • About
  • Contact
  • Disclaimer
  • Copyright
  • Subscribe
  • Submit Articles
  • Forum
  • Helping Hand
  • Part Time Job
  • Learn PLC
  • Game
  • Donate
  • Videos
Inst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books

Practical Questions

In Practical Instrumentation Questions section, you will get industry related technical questions with problem solving approach,

Determine Level of Liquid in the Vessel and its Specific Gravity

Determine Level of Liquid in the Vessel and its Specific Gravity

From these pressure measurements, determine the level of liquid in the vessel and its specific gravity using three transmitters.

Question on Remote Seal with Capillary Tubing Transmitter

Question on Remote Seal with Capillary Tubing Transmitter

The DP transmitter is located 5 feet above the bottom of the vessel and has a remote seal with capillary tubing with fill fluid.

LRV and URV of PT for Extreme Limits of Empty and Full

LRV and URV of PT for Extreme Limits of Empty and Full

Measure water level in the vessel using PT, where the LRV and URV points are both between the extreme limits of empty and full.

Dip Tube Type Level System

Questions on Dip Tube Type Level System

A liquid storage vessel holding a very corrosive liquid has its level measured by a dip tube type level system.

Tank uses 3 Pressure Transmitters to Measure Level & Density

Tank uses 3 Pressure Transmitters to Measure Level & Density

A tank expert system uses three pressure transmitters to measure level and density of a liquid in a large storage vessel.

DP transmitter Elevated 10 Feet above the Vessel

DP transmitter Elevated 10 Feet above the Vessel

Determine the LRV and URV for measuring water level in a vessel with the DP transmitter elevated 10 feet above the vessel.

DP Transmitter Located 10 feet Beneath the Vessel

DP Transmitter Located 10 feet Beneath the Vessel

Determine the LRV and URV of a DP transmitter located 10 feet beneath the vessel and connected to it with capillary tubing.

High Level Alarm of Distillation Process

Investigate High Level Alarm of Distillation Process

Suppose the operator of this distillation process calls you to investigate a high-level alarm he is receiving on LAH-58.

Purge Type Level Transmitter

Purge Type Level Transmitter Questions

Purge type level transmitter used to detect hydrostatic pressure in a vessel for the liquid level measurement applications.

Dry Leg

Calculate 0%, 50%, and 100% Calibration Points for ΔP transmitter

Calculate 0%, 50%, and 100% calibration points for the ΔP transmitter to measure liquid level in the vessel for wet leg and dry leg.

Older posts
Newer posts
← Previous Page1 … Page4 Page5 Page6 … Page25 Next →

FOLLOW US

Categories

Recent Comments

  • Omer Fadl on Weirs and Flumes Flow Measurement
  • Esequiel M Esquibel on Relay circuits
  • Nagendra on Formula for Current 4-20ma to Percentage Conversion
  • Eudardo Bustamante on List of 300 Industrial Instrumentation Questions
  • Eudardo Bustamante on Free Instrumentation Course for Trainee Engineers
  • khayelihle ngcobo on Free Instrumentation Course for Trainee Engineers
  • Ranjeet on Formulas to calculate mA from PV, LRV and URV