Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Protection Relays Interview Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Q & A > Protection Relays Interview Questions & Answers

Protection Relays Interview Questions & Answers

Last updated: January 2, 2020 10:17 am
Editorial Staff
Electrical Q & A
No Comments
Share
4 Min Read
SHARE

Study the electrical engineering technical questions and answers on protection relays to prepare for the job discussions.

Contents
Protection Relays Interview QuestionsWhere does the Negative phase sequence relay is employed?What is the operation principle of the differential relay?Why distance protection is preferred as primary protection compared to overcurrent protection for transmission lines?Why biased differential protection is preferred over simple differential protection?Where Impedance relay, Reactance relay, and Mho relays are employed?What is the percentage differential relay?What are the main functions of Differential Relays?What is meant by “Relay Settings”?Define Plug Setting Multiplier?Where is the directional relay used?For what type of fault does Buchholz relay is employed?How definite time lag is achieved in attraction armature relays?

Protection Relays Interview Questions

Protection Relays Interview Questions & Answers
Protection Relays Interview Questions & Answers

Where does the Negative phase sequence relay is employed?

Negative sequence relay is employed for the protection of generators and motors against unbalanced loading that may arise due to phase to phase faults.

What is the operation principle of the differential relay?

A differential relay operates when the phasor difference of two or more similar electrical quantities exceeds a pre-determined amount.

Why distance protection is preferred as primary protection compared to overcurrent protection for transmission lines?

Distance relay is superior to overcurrent protection for the protection of transmission lines.

Some of the reasons are faster protection, simpler coordination, simpler application, permanent settings without the need for readjustment, less effect of the amount of generation and fault levels, fault current magnitude, permits the high line loading.

Why biased differential protection is preferred over simple differential protection?

Biased differential relay is preferred because its operation is not affected by the trouble arising out of the difference in the CTs ratios for high values of external short circuit currents.

Where Impedance relay, Reactance relay, and Mho relays are employed?

The Impedance relay is suitable for the phase faults relaying for the lines of moderate lengths Reactance type relays are employed for the ground faults while Mho type of relays is best suited for the long transmission lines and particularly where synchronizing power surge may occur.

What is the percentage differential relay?

It is a differential relay where the operating current required to trip can be expressed as a percentage of load current.

What are the main functions of Differential Relays?

Differential Relays must have the following features:

  • High-speed operation
  • High sensitivity
  • Adequate short circuit thermal rating
  • Ability to operate with low values of voltage
  • The burden must not be excessive
  • There should be no voltage and current creep

What is meant by “Relay Settings”?

Relay settings mean the actual value of the energizing or characteristic quantity at which the relay is designed to operate under given conditions.

Define Plug Setting Multiplier?

Plug Setting Multiplier and is defined as the ratio of fault current in the relay coil to the pick-up value.

Where is the directional relay used?

Directional relay is used when graded time overload protection is applied to ring mains and interconnected networks.

For what type of fault does Buchholz relay is employed?

Buchholz relay provides protection only against transformer internal fault.

How definite time lag is achieved in attraction armature relays?

The instantaneous type attraction armature can be made a definite time lag or inverse time lag by using an oil dashpot, an air escapement chamber a clockwork mechanism or by placing a fuse in parallel with it.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Electrical Machines Objective Questions & Answers
Transmission Lines Protection Questions Answers
Top 100 Switchgear and Protection Interview Questions
Electrical Machines Questions and Answers
Transformers Questions & Answers Part-4
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

transformers-questions-answers-part-1

Transformers Questions & Answers Part-1

Electrical Motors Interview Question And Answers

Electrical Motors Interview Question And Answers

Substation Interview Questions Answers

Substation Interview Questions Answers

Power System Protection and Relays Questions & Answers

Power System Protection and Relays Questions & Answers

Induction Motor Interview Questions Answers

Induction Motor Interview Questions Answers

Basic Power Electronics Interview Questions

Basic Power Electronics Interview Questions

Voltage Control & Circuit Breakers Interview Questions

Voltage Control & Circuit Breakers Interview Questions

Advantages & Disadvantages of Air Insulated Substation

Advantages & Disadvantages of Air Insulated Substation

More Articles

FF JB Termination

Foundation Fieldbus Installation and Best Practices

While Do Statement in Structured Text PLC Program

While Do Statement in Structured Text PLC Program

How to set password in Siemens HMI

How to Password Protect HMI in Siemens TIA Portal?

Types of Industrial Level Sensors

Types of Industrial Level Sensors

Instrument Percent of Span Error

Instrument Percent of Span Error

Electro Mechanical Transducers Objective Questions

Electro Mechanical Transducers Objective Questions

Field Instruments Questions and Answers

Basics of Amplifiers Interview Questions

Working of Stepper Motor

Types of Stepper Motors

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?