Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Displacer Level Transmitter Questions
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Displacer Level Transmitter Questions

Displacer Level Transmitter Questions

Last updated: June 6, 2018 9:47 am
Editorial Staff
Practical Questions
No Comments
Share
1 Min Read
SHARE

Displacer Level Transmitter

Question :

Determine a basic 5-point (0%, 25%, 50%, 75%, and 100%) calibration table for the displacer level transmitter in this scenario:

displacer level transmitter configuration

The cylindrical displacer weighs 9 pounds (dry) and has a diameter of 2 inches.

The process liquid is water.

The 0% process liquid level (LRV) is even with the bottom of the displacer.

Assume an electronic transmitter mechanism with an output range of 4 to 20 mA.

Fill the missign fields in the below table.

displacer level transmitter Calibration table

Answer :

displacer level transmitter Calibration Data

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Calculate Amount of Weight Indicated by the Scale
Steam Eductor Question
Programmable Logic Controller (PLC) Questions and Answers – 17
PLC Practice Questions
How Much Pressure Indicated by Micromanometer?
Pressure Gauge with Block and Bleed Valves
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

pH Monitoring System Triggers an Alarm
What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?
Programmable Logic Controller (PLC) Questions and Answers – 6
How to Connect Proximity Switch (Sink Type) to Make LED ON ?
Differential Capacitance Pressure Sensor Circuit
Determine the Status of Lamps and Relays in the Circuit ?
Compressor Emergency Shutdown Root Cause Analysis
Calculate Total Hydrostatic Pressure at Bottom of Vessel

Keep Learning

water seal drum lever transmitter

Determine LRV and URV settings for the Level Transmitter

Three-valve Manifold on Remote Seal DP Transmitter

Three-valve Manifold on Remote Seal DP Transmitter

Connect the Differential Pressure Gauge at the Filter

How Do You Connect the Differential Pressure Gauge at the Filter?

Purge Type Level Transmitter

Purge Type Level Transmitter Questions

compressor emergency shutdown system

Solenoid Valves Questions & Answers – 2

Which Tube has most Hydrostatic Pressure

Which Tube has most Hydrostatic Pressure?

Baffle Nozzle Question

Baffle Nozzle Question

reactor vessel

Practical Process Control System Questions & Answers – 5

Learn More

Calculate Density and Specific Gravity

Calculate Density and Specific Gravity

Positive Displacement Pumps

What are Positive Displacement Pumps and their Types?

Distributed Control System Architecture

Control System Architecture

Ethernet IP Preferred in Large Networking Systems

Why is Ethernet IP Preferred in Large Networking Systems?

ORP-sensor-calibration

Oxidation-Reduction Potential (ORP) Sensor Calibration Procedure

Linear Heat Detector Working Principle

What are Linear Heat Detectors?

Categories of Unshielded Twisted Pair

Network Cabling

Electromagnetic Noise Interference

What is Electromagnetic Noise Interference?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?