Reading: Mathematical Preliminaries
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Mathematical Preliminaries

Mathematical Preliminaries

Last updated: November 27, 2021 5:40 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Mathematical Preliminaries

1. Which of the following devices is used for conversion of co-ordinates?

a) Microsyn
b) Selsyn
c) Synchro-resolver
d) Synchro-transformer

Answer: c

Explanation: Synchro-Resolver is rotary transformer used for measuring degree of rotation and used for the conversion of the co-ordinates.

2. The effect of error damping is to

a) Provide larger settling lime
b) Delay the response
c) Reduce steady state error
d) All of the mentioned

Answer: c

Explanation: Error damping is to reduce steady state error as it is used to enhance the steady state response of the system and this can be done by increasing the damping of the system.

3. ______________technique gives quick transient and stability response

a) Root locus
b) Bode
c) Nyquist
d) Nichols

Answer: a

Explanation: Root locus is the right technique for the quick transient and stability response and gives the final response and quickly.

4. A phase lag lead network introduces in the output

a) Lag at all frequencies
b) Lag at high frequencies and lead at low frequencies
c) Lag at low frequencies and lead at high frequencies
d) None of the above mentioned

Answer: c

Explanation: A phase lag lead network is the combination of the lead and lag network and also it lags at low frequencies and lead at high frequencies.

5. Which of the following is the non-linearity caused by servomotor?

a) Static friction
b) Backlash
c) Saturation
d) None of the mentioned

Answer: c

Explanation: Linearity in the servo-motor is due to the saturation present and which is the important consideration for any type of the practical device.

6. ____________can be extended to systems which are time-varying?

a) Bode-Nyquist stability methods
b) Transfer functions
c) Root locus design
d) State model representatives

Answer: d

Explanation: State model representation is the best advantage for the systems over transfer function approach as it can be applied for the non-linear systems.

7. Laplace transform is used for the systems with:

a) Initial conditions infinite
b) Initial conditions zero
c) Initial conditions finite
d) Initial conditions equal to the initial input

Answer: b

Explanation: By definition of the transfer function by Laplace transform the initial conditions of the systems are considered to be zero.

8. Which of the following is an electromechanical device?

a) Induction relay
b) Thermocouple
c) LVDT
d) All of the mentioned

Answer: c

Explanation: LVDT is the electromechanical device which converts the displacement of the core to the electrical energy by the action of the transformer.

9. A differentiator is usually not a part of a control system because it

a) Reduces damping
b) Reduces the gain margin
c) Increases input noise
d) Increases error

Answer: c

Explanation: A differentiator is generally not the part of the control system as it increases the input noise due to reduced gain and increased bandwidth.

10. If the gain of the critical damped system is increased it will behave as

a) Oscillatory
b) Critically damped
c) Overdamped
d) Underdamped

Answer: a

Explanation: On increasing the gain damping will automatically get reduced and hence the oscillations in the system increases.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Gas Solid Chromatography Questions & Answers
Root Locus Concepts Objective Questions
X-Ray Spectroscopy Questions & Answers
Actuators Questions and Answers
MCQ on Flow Measurement
Infrared Gas Analyzers Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Stepper Motor MCQ
Ion Transducers Questions & Answers
Dissolved Oxygen Analyzer Questions and Answers
Control Valves Multiple Choice Questions
Feedback Compensation
Measurement and Instrumentation Objective Questions – Part 2
Total Reflection Spectrometer Questions & Answers
Inductively Coupled Plasma Mass Spectrometer

Keep Learning

Analytical Measurement Multiple Choice Questions

Analytical Measurement Multiple Choice Questions

Time Response Analysis

Time Response of Second Order Systems – I

Digital Control Systems

The inverse z-transform & Response of Linear Discrete Systems

Control Systems Stability and Algebraic Criteria

Routh-Hurwitz Stability Criterion

Pollution Monitoring Instruments Questions and Answers

Hydrocarbons Questions & Answers

Mathematical Models of Physical Systems

Signal Flow Graphs Objective Questions

Nonlinear Control Systems

Construction of Phase -Trajectories

Analyzers Questions and Answers

H2S Analyzers Questions & Answers

Learn More

Diode-testing-with-multimeter

How to Test a Diode using Multimeter

Schneider Electric Modicon M340 PAC

PLC vs PAC – Understanding the Key Differences and Similarities

Metering pumps

Metering Pumps

A Question on Density Gauge

How to Safely Design Automation System for Hazardous Environments?

Automation System for Hazardous Environments

DC Power Supplies Objective Questions

DC Power Supply Objective Questions

interview-questions-and-answers-on-natural-gas

Oil and Gas Interview Questions Answers

Butterfly check valves

What is Butterfly Check Valve ?

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?