Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Root Locus in Control Systems
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Root Locus in Control Systems

Root Locus in Control Systems

Last updated: November 27, 2021 5:41 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Root Locus in Control Systems MCQ

1. Consider the loop transfer function K(s+6)/(s+3)(s+5) In the root locus diagram the centroid will be located at:

a) -4
b) -1
c) -2
d) -3

Answer: c

Explanation: Centroid =Sum of real part of open loop pole-sum of real part of open loop zeros/P-Z.

2. Which one of the following applications software’s is used to obtain an accurate root locus for?

a) LISP
b) MATLAB
c) dBase
d) Oracle

Answer: b

Explanation: MATLAB stands for mathematics laboratory in which the input is in the form of the matrix and is the best software for drawing root locus.

3. Which one of the following is not the property of root loci?

a) The root locus is symmetrical about imaginary axis
b) They start from the open loop poles and terminate at the open loop zeroes
c) The breakaway points are determined from dK/ds = 0
d) Segments of the real axis are the part of the root locus if and only is the total number of real poles and zeroes to their right is odd.

Answer: a

Explanation: The root locus is the locus traced due to the gain of the system with changing frequency and need not be symmetrical about origin.

4. The breakaway point calculated mathematically must always lie on the root locus.

a) True
b) False

Answer: a

Explanation: The breakaway point of the two branches of the root locus is the point where the two branches either meet or they break and may or may not always lie on the root locus.

5. What is the number of the root locus segments which do not terminate on zeroes?

a) The number of poles
b) The number of zeroes
c) The difference between the number of poles and zeroes
d) The sum of the number of poles and the number of the zeroes

Answer: c

Explanation: The number of the root locus segments which do not lie on the root locus is the difference between the number of the poles and zeroes.

6. Which one of the following are correct?
The root locus is the path of the roots of the characteristic equation traced out in the s-plane?

a) As the input of the system is changed
b) As the output of the system is changed
c) As a system parameter is changed
d) As the sensitivity is changed

Answer: c

Explanation: The root locus is the locus of the change of the system parameters of the characteristic equation traced out in the s-plane.

7. If the gain of the system is reduced to a zero value, the roots of the system in the s-plane,

a) Coincide with zero
b) Move away from zero
c) Move away from poles
d) Coincide with the poles

Answer: d

Explanation: The roots of the system in s plane coincides with the poles if the gain of the system is reduced to a value zero.

8. The addition of open loop zero pulls the root loci towards:

a) The left and therefore system becomes more stable
b) The right and therefore system becomes unstable
c) Imaginary axis and therefore system becomes marginally stable
d) The left and therefore system becomes unstable

Answer: a

Explanation: The system can become stable by reducing the damping and also by adding zeroes in the s plane and moving left of the s plane system becomes more stable.

9. If root loci plots of a particular control system do not intersect the imaginary axis at any point, then the gain margin of the system will be:

a) 0
b) 0.707
c) 1
d) Infinite

Answer: d

Explanation: The gain margin is the inverse of the intersection of the root loci plot to the imaginary axis and if it does not intersect then the gain margin will be infinite.

10. When the number of poles is equal to the number of zeroes, how many branches of root locus tends towards infinity?

a) 1
b) 2
c) 0
d) Equal to number of zeroes

Answer: c

Explanation: Branches of the root locus is equal to the number of poles or zeroes which ever is greater and tends toward infinity when poles or zeroes are unequal.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Hydrogen and Glass Electrodes Questions & Answers
Feedback Control Loop Questions & Answers
Root Locus Concepts Objective Questions
Temperature and Humidity Objective Questions
Digital Control Systems Multiple Choice Questions
Time Response of First Order Systems Objective Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Ammonia and Fluoride Electrode Questions & Answers
Routh-Hurwitz Stability Criterion
Effect of Adding a Zero to a System
Hydrocarbons Questions & Answers
Secondary Reference Electrodes Questions & Answers
Design Considerations for Higher Order Systems
Silica Analyzer Questions & Answers
Measurement and Instrumentation Objective Questions – Part 4

Keep Learning

Ion Analyzers Questions and Answers

Ion Selective Electrodes Questions and Answers

Stability in Frequency Domain

The Design Problem

Feedback Characteristics of Control Systems

Controller Components – Part 1 Objective Questions

Infrared Spectrometers Questions & Answers

Infrared Spectrometers Questions & Answers

Time Response Analysis

Robotic Control System – Part II

Spectrometers Questions and Answers

X-Ray Fluorescence Spectrometry Questions and Answers

Pollution Monitoring Instruments Questions and Answers

Sulphur Di-oxide Monitoring Questions & Answers

Nonlinear Control Systems

Common Physical Nonlinearities

Learn More

Digital Electronics Objective Questions

Digital Electronics Objective Questions – Set 1

Potentiometer Animation

Potentiometer Working Principle Animation

W Type Transit Time Flow Meter

Transit Time Flow Meter – Types, Advantages, Disadvantages

Simple PLC example Hardware configurations

Muting Functions of Safety Control Circuits – PLC Example

SIS Audit & Assessment - Safety Instrumented System

SIS Audit & Assessment – Safety Instrumented System

Control Valve flow coefficient (Cv)

Why we Measure Control Valve flow coefficient (Cv)?

Piping Schematic for Two Solenoid Valves Double Acting

Different Types of Control Valve Actuators

Fire and Gas system Audible and Visual Alarms

Fire and Gas system Audible and Visual Alarms

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?