Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Relative Stability Analysis
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Relative Stability Analysis

Relative Stability Analysis

Last updated: November 27, 2021 5:41 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Relative Stability Analysis MCQ

1. A system with unity feedback having open loop transfer function as G(s) = K(s+1)/s3+as2+2s+1. What values of ‘K’ and ’a’ should be chosen so that the system oscillates ?

a) K =2, a =1
b) K =2, a =0.75
c) K =4, a =1
d) K =4, a =0.75

Answer: b

Explanation: Solving Routh Hurwitz table whenever row of zero occurs, the roots are located symmetrically on the imaginary axis then the system response oscillates, a =1+K/2+K. If K =2 is consider then a =0.75.

2. The open loop transfer functions with unity feedback are given below for different systems. Among these systems the unstable system is

a) G(s) =2/s+2
b) G(s) =2/s(s+2)
c) G(s) =2/(s+2)s^2
d) G(s) =2(s+1)/s(s+2)

Answer: c

Explanation: 1+2/s^2(s+2) =0. The coefficient of‘s’ is missing. Hence the system is unstable.

3. Determine the stability of closed loop control system whose characteristic equation is s5+s4+2s3+2s2+11s+10=0.

a) Stable
b) Marginally stable
c) Unstable
d) None of the mentioned

Answer: b

Explanation: By Routh array s =0 and s =+j. It is having a pair of conjugate root lying on imaginary axis. System is marginally stable.

4. Determine the condition for the stability of unity feedback control system whose open loop transfer function is given by G(s) = 2e-st/s(s+2)

a) T >1
b) T <0
c) T <1
d) T >0

Answer: c

Explanation: G(s) =2(1-sT)/s(s+2)
By Routh array analysis, for stable system, all the elements of first column need to be positive T<1.

5.Determine the value of K such that roots of characteristic equation given below lies to the left of the line s = -1. s3+10s2+18s+K.

a) K>16 and K<9
b) K<16
c) 9<K<16
d) K<9

Answer: c

Explanation: In Routh array analysis the first column must be positive and after solving K<16 and K>9.

6. Consider a negative feedback system where G(s) =1/(s+1) and H(s) =K/s(s+2). The closed loop system is stable for

a) K>6
b) 0<K<2
c) 8<K<14
d) 0<K<6

Answer: d

Explanation: Using Routh array, for stability k<6.

7. The characteristic equation of a feedback control system is s3+Ks2+9s+18. When the system is marginally stable, the frequency of the sustained oscillation:

a) 1
b) 1.414
c) 1.732
d) 3

Answer: d

Explanation: Solve using Routh array and for the system to be marginally stable, K = -2. Polynomial for sustained oscillation w = 3 rad/s.

8. Consider a characteristic equation, s4+3s3+5s2+6s+k+10=0. The condition for stability is

a) K>5
b) -10<K
c) K>-4
d) -10<K<-4

Answer: d

Explanation: Solve Roth array for the system stable, -10<K<4.

9. The polynomial s4+Ks3+s2+s+1=0 the range of K for stability is _____________

a) K>5
b) -10<K
c) K>-4
d) K-1>0

Answer: d

Explanation: Solving using Routh array we get K-1>0 and is always negative for K>1.

10. The characteristic equation of a system is given by3s4+10s3+5s2+2=0. This system is:

a) Stable
b) Marginally stable
c) Unstable
d) Linear

Answer: c

Explanation: There is missing coefficient so system is unstable.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Fourier Transform NMR Spectroscopy Questions & Answers
Mathematical Preliminaries
Measurement and Instrumentation Objective Questions – Part 5
Effect of Adding a Zero to a System – II
Stability Analysis
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Nuclear Magnetic Resonance Spectrometer Questions and Answers

Nuclear Magnetic Resonance Spectrometer Questions & Answers

Nonlinear Control Systems

Stability Analysis by Describing Functions

Chromatography Questions & Answers

Chromatography Questions & Answers

Time Response Analysis

Effect of Adding a Zero to a System

State Variable Analysis and Design

Controllability & Observability

Nuclear Power Plant Multiple Choice Questions

Nuclear Power Plant Multiple Choice Questions

Single Beam and Double Beam Instruments

Single Beam and Double Beam Instruments

Pollution Monitoring Instruments Questions and Answers

Sulphur Di-oxide Monitoring Questions & Answers

More Articles

Fisher model 546 I to P transducer

Fisher model 546 I/P transducer

gate-valve-principle-animation

Basics of Gate Valves

Calculation of Hydrostatic Pressure

Calculation of Hydrostatic Pressure

Difference between Transmitter and Transducer with Examples

Difference between Transmitter and Transducer with Examples

Electric Circuits Objective Questions

Electric Circuits Objective Questions – Set 4

PLC Pressure Switch Ladder Diagram

Relays in Ladder Logic Tutorials

Function of Racks in PLC System

Function of Racks in PLC – Types of SIEMENS S7-400 PLC Racks

Shielded Cables

The Idea Behind Shielded Cables

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?