Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Pneumatic Control Mechanisms Objective Questions
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Pneumatic Control Mechanisms Objective Questions

Pneumatic Control Mechanisms Objective Questions

Last updated: November 27, 2021 5:32 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
7 Min Read
SHARE

Pneumatic Control Mechanisms Objective Questions

1. With a proportional-plus-integral controller, a sustained error will result in:

a. Windup
b. A fixed offset
c. A temporary narrowing of the proportional band
d. A delay in the process

Answer: a

2. By locating the derivative function in the input measurement circuit, which of the following advantages can be realized?

a. Smooth bump-less transfer
b. No derivative bump with a set-point change
c. No proportional response to a set-point change
d. Integral adjustment is isolated from response

Answer: b

3. If proportional-plus-integral control is good, the addition of derivative:

a. Will anticipate changes and speed up corrections
b. Will always improve control
c. Will make the controller adjustments easier to accomplish
d. May create stability problems in some system

Answer: d

4. The advantage of adding derivative to a controller is always:

a. Increased stability
b. The ability to overcome a big pure dead time lag
c. The ability to react more quickly to measurement change
d. A decrease in the pure dead time of the process

Answer: c

5. For fail-safe action the control valve should, upon energy (air) failure:

a. Open
b. Close
c. Move in such direction as to make the process nonhazardous
d. Stay in its previous position

Answer: c

6. If the closed-loop control system has too much gain, it will cycle. The only loop component that has conveniently adjustable gain is the

a. Measuring transmitter
b. Valve operator
c. Process
d. Controller

Answer: d

7. Adjusting the controller for optimum performance:

a. Is not required, because it adjusts itself
b. Requires a special tool
c. Is usually done by trial and error
d. Always requires a very involved mathematical analysis of the process

Answer: c

8. A process is to be controlled using an all pneumatic system. The maximum distance between loop components will be:

a. 1,000 feet
b. 500 feet
c. 200 feet
d. 20 feet

Answer: c

9. If the distance between loop components in the all pneumatic control system must be increased it will require:

a. A pneumatic volume booster
b. Larger sized tubing
c. Smaller sized tubing
d. Conversion to an electrical signal

Answer: d

10. Pneumatic signals travel through the signal tubing at:

a. 100 feet per second
b. Approximately the speed of sound
c. A rate that depends on tubing size
d. Approximately the speed of light

Answer: b

11. The integral dial in a pneumatic controller is calibrated in

a. Minutes or repeats
b. Integral units
c. Gain
d. Percentage
e. Offset

Answer: a

12. In a proportional-only controller, if the measurement equals the set point the output will equal the bias. True or False ?

a.True
b. False

Answer: a

13. In an integral controller, the rate of change of the output is proportional to the error. True or False ?

a.True
b. False

Answer: a

14. The larger the number on the integral dial the greater the effect of the integral action. True or False ?

a.True
b. False

Answer: b

15. In a batch operation, if a controller has wound up, it is quite possible that the valve may stay in an extreme position until the measurement actually goes beyond the set point before the valve begins to change its position. True or False ?

a.True
b. False

Answer: a

16. What some manufacturers call rate others call derivative ? True or False ?

a.True
b. False

Answer: a

17. Indicate all correct Statements. For each statement True or False ?

a.Gain is the reciprocal of the proportional band.
b. The proportional band is the reciprocal of gain.
c. The proportional band times the gain equals 1.
d. The gain divided by the proportional band equals 1.
e. The narrower the proportional band, the higher the gain.
f. The wider the proportional band, the lower the gain.

Answer :  a – True, b – True, c – True, d – False, e – True, f – True,

18. In a process controlled by a proportional-plus-integral controller, the measurement was at the set point and the output was 9 psi (60 kPa). The measurement then quickly decreased to a certain value below the set point and leveled out there. The output responded by changing to 8 psi (55 kPa). As time progresses, what would you expect from the output pressure?

a. Increase to 9 psi (60 kPa) to bring the measurement back to the set point
b. Remain at 8 psi (55 kPa) as long as the measurement stays where it is.
c. Decrease and continue to decrease to 3 psi (20 kPa).
d. Continue to decrease until the measurement reaches the set point, or if it does not return to the set point, decrease to 0 psi.

Answer: d

19. The range of the temperature measuring system used in conjunction with a Model 130 proportional-only controller is 0 to 150°f (66°C). The output is 9 psi (60 kPa) when the set point and indicator are both at 75°f (24°C). If the proportional band is 200 percent, what is the output when the measurement is 150°f (66°C)?

a. 9 psi (60 kPa)
b. 3 psi (20 kPa)
c. 12 psi (83 kPa)
d. 15 psi (100 kPa)

Answer: c

20. If the span of a measuring transmitter in a control system is made one-half of its value, the proportional-band adjustment in the controller must be -to maintain the same quality of control.

a. Cut in half
b. Doubled
c. Squared
d. Narrowed

Answer: b

NOTE : Pneumatic Controls are outdated in practical industries. These are shared for learning the basics.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Process Control Questions & Answers
Dissolved Oxygen Analyzer Questions and Answers
Infrared Gas Analyzers Questions & Answers
Biosensors Questions & Answers
Ion Analyzer Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Digital Circuits Questions & Answers

Digital Circuits Questions & Answers

Encoder Questions

Encoder Multiple Choice Questions

Time Response Analysis

Effect of Adding a Zero to a System

IR Instrumentation Questions & Answers

IR Instrumentation Questions & Answers

Programmable Logic Controllers Multiple Choice Questions

Programmable Logic Controllers Multiple Choice Questions

Nonlinear Control Systems

Constructing Phase-Trajectories

Control Systems Multiple Choice Questions

Pollution Monitoring Instruments Questions and Answers

Carbon Monoxide Questions & Answers

More Articles

Variable Air Volume Controller in HVAC

What is Variable Air Volume Controller in HVAC?

Electrical and Instrumentation Engineering Documents

Electrical and Instrumentation – Automation Pre-engineering Documents

What is IO-Link in Smart Manufacturing

What is IO-Link in Smart Manufacturing?

80+ PLC MCQ

80+ PLC MCQ Questions

Electrical Machines Questions and Answers

DC Motors Characteristics Quiz

Bus Riser in Switchgear

Bus Riser in Switchgear

Claw Machine PLC Programming

Doll Claw Machine using Omron PLC Programming

Infrared Flue Gas Analyser

What is Infrared Flue Gas Analyzer? – Working Principle

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?