Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Electron Spectroscopy for Chemical Analysis
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Electron Spectroscopy for Chemical Analysis

Electron Spectroscopy for Chemical Analysis

Last updated: November 27, 2021 5:37 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
5 Min Read
SHARE

Electron Spectroscopy for Chemical Analysis

1. The kinetic energy of the photoelectron energies is dependent on _________ of the atom, which makes XPS useful to identify the oxide state.

a) Mass
b) Charge
c) Chemical environment
d) Volume

Answer: c

Explanation: The kinetic energy of the photoelectron energies is dependent on chemical environment of the atom, which makes XPS useful to identify the oxide state. It also helps to identify the ligands of the atom.

2. Ion etching techniques provides the depth profiling from the surface.

a) True
b) False

Answer: a

Explanation: Ion etching techniques provides the depth profiling from the surface. Binding energy can also be used.

3. Electron spectroscopy is based on the ionization phenomenon.

a) True
b) False

Answer: a

Explanation: Electron spectroscopy is based on the ionization phenomenon. It can be ionization of photon or electron.

4. The kinetic energy of the ejected photoelectron is dependent upon the energy of which of the following?

a) Ions around
b) Photons around
c) Material
d) Impinging photon

Answer: d

Explanation: The kinetic energy of the ejected photoelectron is dependent upon the energy of impinging photon. A free electron is ejected.

5. ESCA gives sufficient chemical information up to a depth about ________ armstrong in metals.

a) 5-20
b) 15-40
c) 40-100
d) 100-200

Answer: a

Explanation: ESCA gives sufficient chemical information up to a depth about 5-20 armstrong in metals. ESCA is also known as X-ray photoelectron spectroscopy.

6. ESCA gives sufficient chemical information up to a depth about ________ armstrong in polymers.

a) 5-20
b) 15-40
c) 40-100
d) 100-200

Answer: c

Explanation: ESCA gives sufficient chemical information up to a depth about 40-100 armstrong in polymers. ESCA is also known as X-ray photoelectron spectroscopy.

7. ESCA gives sufficient chemical information up to a depth about ________ armstrong in oxide.

a) 5-20
b) 15-40
c) 40-100
d) 100-200

Answer: b

Explanation: ESCA gives sufficient chemical information up to a depth about 15-40 armstrong in oxide. ESCA is also known as X-ray photoelectron spectroscopy.

8. ESCA can identify elements in the periodic table above which of the following?

a) Carbon
b) Boron
c) Helium
d) Potassium

Answer: c

Explanation: ESCA can identify elements in the periodic table above helium. Adjacent elements are clearly distinguished.

9. Discrete electrons cannot be observed in electron ionization of an atom due to which of the following reasons?

a) Environmental disturbances
b) Same mass
c) Same charge
d) Electron- electron interaction

Answer: d

Explanation: Discrete electrons cannot be observed in electron ionization of an atom because of electron-electron interaction. Therefore, ESCA cannot be observed when using electron ionization.

10. ESCA focusses on which of the following information?

a) Mass of the electron
b) Charge of the electron
c) Binding energy of the electron
d) Mass of atoms

Answer: c

Explanation: ESCA focusses on binding energy of the electrons. It focusses on the binding energy which the electrons had before they left the atom.

11. In the spectrum, two main peaks at _________ and ________ are observed.

a) 284.6, 532.5
b) 248.6, 523.5
c) 264.8, 535.2
d) 246.8, 553.2

Answer: a

Explanation: In the spectrum, two main peaks at 284.6 and 532.5 are observed. The unit for counting energy is electron-volt.

12. 284.6 eV matches which of the following specific atom type?

a) Carbon
b) Oxygen
c) Nitrogen
d) Argon

Answer: a

Explanation: Each energy matches a specific atom type. 284.6 eV matches carbon.

13. 532.5 eV matches which of the following specific atom type?

a) Carbon
b) Oxygen
c) Nitrogen
d) Argon

Answer: b

Explanation: Each energy matches a specific atom type. 532.5 eV matches carbon.

14. By studying which of the following can we determine if the surface corresponds to C-O or C=O chemical form?

a) Mass of the electron
b) Energy of the carbon peak
c) Binding energy
d) Charge of electron

Answer: b

Explanation: By studying energy of the carbon peak it can be determined if the surface corresponds to C-O or C=O chemical form. Thus, the specimen chemical composition can be obtained.

15. Which of the following is the detection limit of ESCA?

a) 0.1% monolayer
b) 0.5% monolayer
c) 1% monolayer
d) 2% monolayer

Answer: a

Explanation: The detection limit of ESCA is 0.1% monolayer. It has no x-y resolution

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Components of Mass Spectrometer Questions & Answers
Instrumentation of ESR Spectrometer
State Models for Linear Continuous Time Systems
Level and Density Measurement Objective Questions
Feedforward Control Questions and Answers
Approximation of Higher-Order Systems by Lower Order
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Block diagram Algebra Objective Questions
Auger Electron Spectroscopy
Total Reflection Spectrometer Questions & Answers
Feedback Compensation
Instrument Calibration Multiple Choice Questions
Top 10 Industrial safety Objective Questions
Necessary Conditions for Stability & Non-Linear Systems
The Z-Transform
Solution of State Equations
Stepper Motor MCQ

Keep Learning

Advances in Control System

Fuzzy Logic Control

Temperature Measurement Multiple Choice Questions

Temperature Measurement Multiple Choice Questions

Stability in Frequency Domain

Closed-Loop Frequency Response

Absorption Instrumentation Questions & Answers

Absorption Instrumentation Questions & Answers

Electron Spin Resonance Questions & Answers

Electron Spin Resonance

Ion Spectrometers Questions & Answers

Ion Spectroscopy Questions & Answers

Liapunov’s Stability Analysis

Direct Method & Constructing of Liapunov for the Linear & Non-Linear System

pH Analyzers Questions and Answers

pH Measurement Questions & Answers

Discover More

Blowdown Valve (BDV) and Shutdown Valve (SDV)

Difference between Blowdown Valve (BDV) and Shutdown Valve (SDV) ?

Telemetry Systems Objective Questions

Telemetry Systems Objective Questions

Cathode Ray Oscilloscope Questions & Answers

Cathode Ray Oscilloscope Questions & Answers

Pressure Gauge Accessories

Pressure Gauge Accessories Questions and Answers

Digital Electronics Multiple Choice Questions

Multiplexers Objective Questions – Part 1

Automation in Logistics Industry

Automation in Logistics Industry

Failsafe interlock Design

Failsafe Wiring Practices

Top 100 Power Systems Projects

Top 100 Power Systems Projects – Electrical Engineering

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?