Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Hydrocarbons Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Hydrocarbons Questions & Answers

Hydrocarbons Questions & Answers

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Hydrocarbons Questions & Answers

1. Which of the following methods cannot be used for the estimation of hydrocarbons?

a) Mass spectroscopy
b) Chemiluminescence method
c) Ultraviolet absorption
d) Gas chromatography

Answer: b

Explanation: Chemiluminescence method cannot be used for the estimation of hydrocarbons. This is because hydrocarbons do not produce chemiluminescence effect.

2. Which of the following is the most abundant hydrocarbon which is emitted into the atmosphere by biological activity?

a) Ethane
b) Methane
c) Poly Aromatic hydrocarbons
d) Pentane

Answer: b

Explanation: The most abundant hydrocarbon which is emitted into the atmosphere by biological activity is methane. It is also emitted by automobile exhausts, burning of coal, etc.

3. Flame ionization detectors are sensitive to which of the following gases?

a) Carbon dioxide
b) Methane
c) Carbon monoxide
d) Sulphur dioxide

Answer: b

Explanation: Flame ionization detectors are sensitive to methane since, they are sensitive to organic compounds. They are insensitive to non-combustible gases. Hence, they are not sensitive to carbon monoxide, carbon dioxide and sulphur dioxide.

4. How can carbon monoxide be detected using flame ionization detectors while using gas chromatography technique?

a) By converting it into carbon di-oxide
b) By converting it into methane
c) By mixing it with combustible gases
d) It cannot be detected

Answer: b

Explanation: Carbon monoxide cannot be detected directly using flame ionization detectors while using gas chromatography technique. Hence, it is converted into methane and is then detected.

5. Which of the following organic compounds will have the highest intensity of response when introduced in a flame ionization detector?

a) Methane
b) Ethane
c) Propane
d) Butane

Answer: d

Explanation: Butane will have the highest intensity of response when introduced in a flame ionization detector. This is because the intensity of response will be in proportion with the number of carbon atoms in the chain.

6. Propane would give three times the intensity of response as compared to methane.

a) True
b) False

Answer: a

Explanation: Propane would give three times the intensity of response as compared to methane. This is because the intensity of response will be in proportion with the number of carbon atoms in the chain.

7. In flame ionization detectors, which of the following is the range adequate for atmospheric sampling?

a) 0-1 ppm
b) 0-2 ppm
c) 0-20 ppm
d) 0-100 ppm

Answer: c

Explanation: In flame ionization detectors, the range adequate for atmospheric sampling is 0-20ppm. It is useful for detecting organic compounds.

8. Which of the following methods make use of pyrolysis while used for detecting methane?

a) Mass spectroscopy
b) Flame ionization detector
c) Ultraviolet absorption
d) Gas chromatography

Answer: b

Explanation: Flame ionization detector makes use of pyrolysis while used for detecting methane. It is used to detect organic compounds.

9. In flame ionization detector, the ions collected on the negatively charged grid are amplified at the high impedance amplifier.

a) True
b) False

Answer: b

Explanation: In flame ionization detector, the ions collected on the positively charged grid are amplified at the high impedance amplifier. Its output is given to the chart recorder.

10. Which of the following is not the characteristic of flame ionization detector?

a) Good linearity
b) Narrow range of concentration
c) High sensitivity
d) Fast response

Answer: b

Explanation: Narrow range of concentration is not the characteristic of flame ionization detector. It has a broad range of concentration.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Electron Probe Microanalyser Questions & Answers
Process Control Questions & Answers
Silica Analyzer Questions & Answers
Split-Range, Auto-Selector, Ratio & Cascade Systems
Common Physical Nonlinearities
Liquid Chromatograph- Mass Spectrometer
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Instrumentation for Electron Spectroscopy
Biosensors Questions & Answers
Construction of Phase -Trajectories
Feedback and Non-feedback Systems Objective Questions
Relative Stability Analysis
Necessary Conditions for Stability & Non-Linear Systems
Analyzers Based on Gas Density Questions & Answers
Constructing Phase-Trajectories
Construction of Root Loci
Diagonalization

Keep Learning

Liapunov’s Stability Analysis

Direct Method & Constructing of Liapunov for the Linear & Non-Linear System

Digital Control Systems

Difference Equations

Spectrometers Questions and Answers

X-Ray Diffractometers Questions & Answers

Time Response Analysis

Time Response of Second Order Systems – IV

Analyzers Questions and Answers

H2S Analyzers Questions & Answers

Advances in Control System

Neural Networks

Electron Spin Resonance Questions & Answers

Instrumentation of ESR Spectrometer

Mathematical Models of Physical Systems

Transfer Functions Objective Questions

Discover More

Performance of Systems Objective Questions

Performance of Control Systems Objective Questions

Types of Equipment Needed to Run a Successful Auto Repair Shop

Types of Equipment Needed to Run a Successful Auto Repair Shop

PLC Programming for Pumping and Draining System

PLC Programming for Pumping and Draining System

Digital Circuits Questions & Answers

Digital Circuits Questions & Answers

Digital Electronics Multiple Choice Questions

Counter Implementation Objective Questions

What is PID Controller

What is PID Controller?

Motor Cooling Methods

Motor Cooling Methods

working-of-pnp-transistor

Working of NPN Transistor

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?