Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Infrared Spectrometers Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Infrared Spectrometers Questions & Answers

Infrared Spectrometers Questions & Answers

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
1 Comment
Share
6 Min Read
SHARE

Infrared Spectrometers Questions & Answers

1. Which of the following is not true about Fourier Transform Infrared (FTIR) spectrometer?

a) It is of non-dispersive type
b) It is useful where repetitive analysis is required
c) Size has been reduced over the years
d) Size has increased over the years

Answer: d

Explanation: FTIR is of non-dispersive type of instruments and is used for repetitive analysis. Initially, it was bulky and cost was high and hence, it was limited to special application. Now, the size has been reduced.

2. In the most widely used beam splitter, a thin film of ________ is sandwiched between two plates of low refractive index solid. Fill the blank with the suitable option.

a) Mylar
b) Silicon carbide
c) Ferrous oxide
d) Silver chloride

Answer: a

Explanation: Generally, mylar is the thin film used in beam splitters. Beam splitter has to pass 50% of the radiation and reflect 50% of the radiation.

3. Which of the following is not the function of drive mechanism in Fourier Transform Infrared Spectrophotometer?

a) Movement of mirror to obtain a satisfactory interferogram
b) Acquire a good interferogram pattern
c) Allow 50% of the beam to pass
d) Keep the speed of the moving mirror constant

Answer: c

Explanation: Drive mechanism does the functions specified in the other options. It the function of the beam splitter to allow 50% of the beam to pass through.

4. Only pyroelectric transducer or pyroelectric crystals are used as detectors in Fourier Transform Infrared Spectrophotometer (FTIR). What is the main reason for other types of thermal detectors are not being used in FTIR spectrophotometer?

a) Less accuracy
b) Slower response
c) Less precision
d) Less sensitivity

Answer: b

Explanation: Other thermal detectors are not employed due to slower response of the detectors. Pyroelectric transducers or pyroelectric crystals are chosen for their high speed, accuracy, precision, sensitivity and resolution.

5. Which of the following is not the advantage of Fourier Transform Spectrometers?

a) Signal to noise ratio is high
b) Information could be obtained on all frequencies
c) Retrieval of data is possible
d) Easy to maintain

Answer: d

Explanation: The instrument is not easy to maintain and it is a disadvantage. The other disadvantage is that the cost is high.

6. Which of the following has to be computed to determine transmittance and absorbance at various frequencies?

a) Ratio of signal and noise
b) Ratio of sample and reference spectra
c) Sample spectra
d) Reference spectra

Answer: b

Explanation: The ratio of sample and reference spectra needs to be computed to determine transmittance and absorbance. First, reference interferogram is obtained and then sample is obtained.

7. Computer accepts analog signals directly.

a) True
b) False

Answer: b

Explanation: Computer does not accept analog signals directly. An A/D converter is required to feed the signals to the computer.

8. Which of the following is the reference that is generally used in FTIR interferometer?

a) Air
b) NaCl solution
c) Alcohol
d) Base solution

Answer: a

Explanation: Air is generally used as the reference. It is scanned for about 20 to 30 times and the results are stored in a computer.

9. In Michelson Interferometer, if the reflected and transmitted beams are in phase at the beam splitter, then maximum intensity will reach the detector.

a) True
b) False

Answer: a

Explanation: If the reflected and transmitted beams are in phase at the beam splitter then maximum intensity will reach the detector. If they are out of phase, then minimum intensity will reach the detector.

10. The diagram given below is the representation of Fourier transform interferometer. Identify the missing block in the block diagram.

a) Pyroelectric crystal
b) Display
c) High speed plotter
d) A/D converter

Answer: d

Explanation: Computer does not accept analog signals directly. An A/D converter is required to feed the signals to the computer.

11. In Michelson’s interferometer, the frequency of the detector output can be determined by translating the _________ of movable mirror and the ___________ of monochromatic radiation.

a) Velocity, wavelength
b) Thickness, intensity
c) Length, velocity
d) Angle, intensity

Answer: a

Explanation: The frequency can be determined by translating the velocity of the movable mirror and the wavelength of monochromatic radiation. The reflected beam passes towards the movable mirror.

12. In Michelson’s interferometer, the __________ of the detector output will depend upon the intensity of incoming radiation.

a) Velocity
b) Frequency
c) Amplitude
d) Phase

Answer: c

Explanation: In Michelson’s interferometer, the amplitude of the detector output will depend upon the intensity of incoming radiation. If movable mirror is moved uniformly, the output will be a sine wave.

13. Why is the computer necessary in Fourier Transform Spectrometer?

a) To display the detector output
b) To process the detector output
c) To determine the amplitude
d) To determine the frequency

Answer: b

Explanation: The computer is necessary to process the output of the detector. The Fourier Transform of output is determined using software using computers.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Pneumatic Control Mechanisms Objective Questions
Paramagnetic Oxygen Analyzers Questions & Answers
Encoder Multiple Choice Questions
Types of NMR Spectrometers Questions & Answers
Instrument Calibration Multiple Choice Questions
Fluorescent Spectrometer Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Kajal says:
    December 16, 2021 at 12:01 pm

    Very helpful thank you

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Time Response of Second Order Systems – II
Analytical Measurement Multiple Choice Questions
Top 100 Power Plant Engineering Objective Questions & Answers
Performance Indices
MCQ on Flow Measurement
Liquid Scintillation Counters Questions & Answers
Constructing Phase-Trajectories
Components of Mass Spectrometer Questions & Answers
State Variables & Linear Discrete Time Systems
Root Locus Concepts Objective Questions

Keep Learning

Mass Spectrometer Questions and Answers

Inductively Coupled Plasma Mass Spectrometer

Mathematical Models of Physical Systems

Transfer Functions Objective Questions

Process Pressure Measurement Objective Questions

Process Pressure Measurement Objective Questions

Feedback Characteristics of Control Systems

Control of the Effects of Disturbance Signals by Use of Feedback

State Variable Analysis and Design

Solution of State Equations

Pneumatic Systems Objective Questions

Pneumatic Systems Objective Questions

Radiochemical Questions and Answers

Gamma Camera Questions & Answers

Nonlinear Control Systems

Stability of Nonlinear System – II

Discover More

Ultrasonic Flow meters Working Animation

Ultrasonic Flow Meters Animation

Diaphragm

Diaphragms

DCS Quiz

DCS Quiz

Distributed Control System Interview Questions

PLC Program

PLC Program to Heat and Bend Glass Tubes

Case Statement in SCL Language

Case Statement in SCL Language

AC Generator Operation

Losses in AC Generator

Two pressure switches

Identify Two Pressure Switches Logic

Follow US