Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Current Limiting Reactors and Short Circuit Currents
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Power Systems > Current Limiting Reactors and Short Circuit Currents

Current Limiting Reactors and Short Circuit Currents

Last updated: September 20, 2016 2:15 pm
Editorial Staff
Power Systems
No Comments
Share
3 Min Read
SHARE

A current limiting reactors is also called as series reactors. It is an inductive coil having large inductive reactance compared to the resistance and is used to limit the short circuit current during fault conditions. These reactors are connected in feeders and ties, in generator leads and between the bus sections to reduce the magnitude of the short circuit current. The reactor allow free interchange of power under normal condition. however during fault condition the disturbance is confined to only faulty location.As the resistance of the reactors are small compared to reactance the efficiency of the system is not affected much

Short circuit current is reduced by an increase in the reactance of the system. Short circuit current depends on the generating capacity, voltage at the fault point and the total reactance between the generating point and the fault location. Breaking capacity of the circuit breaker depends on the magnitude of the fault current. If the fault current is beyond the designed limit of the breaking capacity of the breaker, the fault cannot be extinguish. Therefore in large interconnected power system large number of generators and motors feed the fault on occurrence of the fault. Therefore at times the magnitude of the short circuit current exceeds the breaking capacity of the breaker. Therefore it is necessary to limit the fault current by some means. By including a reactor or few reactors at some strategic locations, short circuit currents at different points can be reduced.

Advantages:

  • Protective reactors are used to reduce the flow of short circuit current at the fault point so as to protect the apparatus from excessive mechanical stresses and from over heating and thus protect the system as a whole
  • Protective systems are used to reduce the voltage disturbances caused by the short circuits
  • They also localize the fault by limiting the current that flow in to the fault from other healthy feeders or parts of the system thereby avoiding the fault by spreading
  • It helps to reduce the duty imposed on the switching equipment during fault conditions

Disadvantages:

  • Total percentage reactance of the system increases thereby causing increase in reactive voltage drop and decrease in power factor due to increased angle of lag. Thus regulation of the system becomes poor.
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Reactive Power Sources and Sinks in Power System
Ungrounded or Isolated Neutral System Disadvantages
Underground Cable Fault Identification Methods
Silicon Carbide Lightning Arresters Working Principle
Factors affect Voltage Level Selection in Service System
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Shunt Vs Series Capacitors Advantages

Shunt Vs Series Capacitors Advantages

Auto Recloser Circuit Breaker in Power System

Auto Recloser Circuit Breaker in Power System

Why Grounding

Generating Station Grounding Principles

Transformer Tap changer

Ferroresonance in Power Transformers

Rotor Angle Stability of Synchronous Generators in Power System

Rotor Angle Stability of Synchronous Generators in Power System

harmonics-effect-on-induction-motor

Harmonics effect on Induction Motor

Power System Protection Quiz

Electrical Power System Protection Quiz

neutral-grounding-practice-in-power-system

Neutral Grounding Practice in Power System

More Articles

Pressure Transmitter Parts

Differential Pressure Transmitter Working Principle

Digital Electronics Multiple Choice Questions

Programmable Array Logic Objective Questions

U-tube Water Manometer

How much Pressure applied to U-tube Water Manometer?

Difference between Availability, Reliability & SIL

Difference between Availability, Reliability & SIL

ESD System Insights

ESD System Insights: Signals for Emergency Valve Shutdown Explained

Types of Switches

Electrical Switches Principle & Types

Fail-Close Valve

What is a Fail-Close Valve? – Advantages and Disadvantages

Advantages of Star and Delta Systems

Advantages of Star and Delta Systems

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?